10.46243/jstj.2019.v4.i4.100 registered
Controlling Drum Level of a Boiler Using Fuzzy Logic Controller
Resolves to https://www.jst.org.in/index.php/pub/article/view/100
Held by Longman Publishers (India) · prefix 10.46243 live · DOI address https://doi.org/10.46243/jstj.2019.v4.i4.100
Registered 29 Sep 2026 via crossref · record version 2 · last change 29 Sep 2026, 11:59 PM · record sha256 16d0a50885779ab0…
Resolve ⬇ Record (JSON) ⬇ Kernel Metadata Declaration (XML) Compare with Crossref Cite (APA · BibTeX · RIS · CSL)
Also as schema.org JSON-LD · Turtle · RDF/XML · DataCite XML · Crossref UNIXREF · Crossref UNIXSD — the formats of the DOI content-negotiation service, from this record (which carries what).
What the DOI identifies
JournalArticle — an article in a journal · Digital · Visual · en
Controlling Drum Level of a Boiler Using Fuzzy Logic Controller (PrincipalTitle · en)
Published 2019-07-10
Part of Journal of Science & Technology · ISSN 2456-5660 · volume 04 · issue 04 · pages 19–30
Agents
- K V V Satya Ganesh (author)
- A.Jawahar (author)
- Ch.Vishnu Chakravarthy (author)
- Longman Publishers (publisher)
Identifiers DOI 10.46243/jstj.2019.v4.i4.100
Abstract · en
Presently used modern techniques to control instead of the traditional control techniques for many industrial applications virtually or theoretically. In this paper, a Fuzzy logic has been applied to control the important variable of steam generator i.e., drum level. It was used simulation of Fuzzy system in MATLAB program. The results showed that the adoption of control technique that based on Fuzzy logic have a high response to indicate the control signals and thus can be depended as an active control system for selecting a right decisions compared with traditional systems. A very common control problem, and one used in many examples elsewhere, is that of controlling the level in a boiler drum. Many industrial plants have boilers for generating process steam, and of course boilers are central to thermal power generation. The boiler drum is where water and steam are separated. Controlling its level is critical – if the level becomes too low, the boiler can run dry resulting in mechanical damage of the drum and boiler piping. If the level becomes too high, water can be carried over into the steam pipe work, possibly damaging downstream equipment. Steam boiler provides appropriate quality and quantity of steam to the turbine for power generation. In drum type boiler, water and steam flow in the drum is controlled in such a way that the water level in the drum is maintained fairly at a preset value. While very low water level in the drum may lead to starvation and explosion of boiler, too high level may cause carryover of water particle and damages the superheaters. Therefore Drum level is an important parameter for safe operation of a boiler. Drum level in a drum type boiler is influenced by number of factors, such as sudden change in load demand and changed in heat input to the boiler etc. During Boiler Feed Pump (BFP) runback, the boiler steam generation is reduced through fuel cut off while steam out flow to the turbine is controlled by pressure controller. Under such circumstance, due to mismatch between steam out and feed water in, it becomes difficult in maintaining water level in the drum to its pre set value. This paper has suggested an innovative drum level control by adopting the Fuzzy controller. It module uniquely co- relates two independent time varying parameters namely steam flow and feed water flow in real time and accordingly apply correction of steam flow to match steam and water flow during BFP runback. Simulation result shows real time correction of steam flow maintains drum level within its safe operating limit during BFP runback. The innovative related rate module can be used as a control block in the future boiler controls for coordination between many parameters varying independently with respect to time. The adoption of fuzzy logic in control system gave the ability to take on decision for control signals with a high stability compared with traditional methods. The fuzzy system contributed in giving prophesies for station case to tell the operator what to do therefore enhancement the performance of station through to take a right decision to avoid stopping.
System metadata — ISO 26324:2025, Annex B · DOI Handbook 10.1
Each element by the standard's name (Annex B: reference elements, then administrative) and the Handbook's (in grey), read off the record above.
| Element | Value | In the record |
|---|---|---|
| DOI Name DOI name | 10.46243/jstj.2019.v4.i4.100 | doi |
| Referent Type referentType | Creation | referent |
| Referent Sub-Type referentSubType | JournalArticle — an article in a journal | type |
| Referent Name(s) referentName(s) | Controlling Drum Level of a Boiler Using Fuzzy Logic Controller (PrincipalTitle, en) | titles |
| Basic Metadata basicMetadata | author: K V V Satya Ganesh author: A.Jawahar author: Ch.Vishnu Chakravarthy publisher: Longman Publishers published: 2019-07-10 part of: Journal of Science & Technology · ISSN 2456-5660 · vol. 04 · no. 04 · pp. 19–30 language: en form: Digital · Visual · Language | agents, dates, container, language, structural_type, modes, characters |
| Referent Identifier(s) alternateIdentifier(s) | none besides the DOI | identifiers, relations (IsSameAs) |
| Registration Authority registrationAuthorityCode | Crossref — issued by Crossref (member 25296); held here as a copy | record.source_agency (our code, ra_doi_name, for names issued here once appointed) |
| Created Date issueDate | 2026-09-07 | record.registered (when the DOI name was first registered) |
| relatedIdentifiers | none needed — the descriptive metadata is in this record | container, relations (only where the descriptive metadata lives at another identifier) |
complete Every System Metadata element is here, with the basic metadata a journal article needs.
The System Metadata Declaration (JSON) · the Kernel Metadata Declaration (XML) · what each sub-type needs
Cited by — in this registry
No record held in this registry cites this DOI.
Counts only records held in this registry; a citation from a work held elsewhere is not seen here. The list as JSON
Relations
The record states no relation, and no record held here states one with this DOI.
Funding
The record names no funder.
Each funder's page lists every work held here that names it. ROR IDs open at ror.org; Funder Registry IDs resolve at doi.org.
History — the ledger
Every change to this DOI, in order, as it was recorded. Entries are only ever added, never changed or removed.
| # | When | What | By | Changes |
|---|---|---|---|---|
| 1 | 29 Sep 2026, 10:00 PM | register registered at Crossref; record read from api.crossref.org | Administrator (admin) | 74 fields set · sha256 69167d6002c5… |
| 2 | 29 Sep 2026, 11:59 PM | update record re-read from api.crossref.org | Administrator (admin) | container.titles.0.value: |
Machine-readable: the history as JSON, with the full record after each change.
Changes made at Crossref through DOI Doctor
Every deposit Smart Scholars' DOI Doctor made for this DOI, oldest first, with Crossref's own answer. Each fingerprint is the SHA-256 of its entry and of the fingerprint before it, so a change to any earlier entry changes every fingerprint after it.
| When | What changed | Crossref | Fingerprint |
|---|---|---|---|
| 11 Sep 2026, 05:25 | Address updated from https://www.jst.org.in/index.php/pub/article/view/100/86 to https://www.jst.org.in/index.php/pub/article/view/100 | ● accepted by Crossref | 0cbb834e9303… |
| 13 Sep 2026, 01:42 | Read back: the DOI resolves to the new address | ● confirmed | 624ab525458e… |
| 21 Sep 2026, 01:51 | Metadata completed publication date | ● waiting for Crossref's answer | f8ff0492cece… |
| 21 Sep 2026, 02:39 | Read back: Crossref's record shows it | ● confirmed | 8a4c5ab462e0… |
4 entries · the last fingerprint 8a4c5ab462e03b7b2b05053058ec22174c2e501d99c7620f7283b4307407fa01 · the history as JSON, each entry with the fingerprint before it, to check them yourself.



