10.46243/jstj.2018.v3.i4.198 registered
Effective Power Utilization Strategy of Fuel Cell System Using FSTP Sepic Inverter
Resolves to https://www.jst.org.in/index.php/pub/article/view/198
Held by Longman Publishers (India) · prefix 10.46243 live · DOI address https://doi.org/10.46243/jstj.2018.v3.i4.198
Registered 29 Sep 2026 via crossref · record version 2 · last change 29 Sep 2026, 11:59 PM · record sha256 fac2711f5f2ec893…
Resolve ⬇ Record (JSON) ⬇ Kernel Metadata Declaration (XML) Compare with Crossref Cite (APA · BibTeX · RIS · CSL)
What the DOI identifies
JournalArticle — an article in a journal · Digital · Visual · en
Effective Power Utilization Strategy of Fuel Cell System Using FSTP Sepic Inverter (PrincipalTitle)
Published 2018-07-01
Part of Journal of Science & Technology · ISSN 2456-5660 · volume 03 · issue 04 · pages 20–31
Agents
- A. Arun Vikram (author)
- R. Ram Kumar (author)
- R. Navaneeth (author)
- G. Gokulakrishnan (author)
- Longman Publishers (publisher)
Identifiers DOI 10.46243/jstj.2018.v3.i4.198
Abstract
Four-Switch mode Three-Phase (FSTP) inverter is considered as an advanced inverter structure to diminish the price, complication, dimension and losses during its switching. The traditional FSTP inverter usually achieves merely buck DC-AC type conversion and highest voltage of the FSTP structured inverter is same as V/2√3. Therefore, the output side line voltage cannot go beyond this rate. To improve the VUF( voltage utilization factor) and reliability of the conventional FSTP inverter, the FSTP SEPIC inverter is considered in this research work, in which both the buck and boost DC-AC conversion is achieved. The double integral Sliding-Mode Control (SMC) is utilized to optimize its dynamics and also it is utilized to confirm whether strength of the whole system at various operating situations is upto the limit. Parameter design, element ranges, and the working of the FSTP-SEPIC based inverter are also offered. The MATLAB Simulink model is used to validate the concept of power utilization of Fuel Cell (FC) by the FSTP-SEPIC inverter. Simulation result shows the efficiency of the inverter , both the buck and boost operation with FC input. The inverter efficiency and other outputs of buck and boost inverter operation with FC input is exhibited using Simulation.
System metadata — ISO 26324:2025, Annex B · DOI Handbook 10.1
Each element by the standard's name (Annex B: reference elements, then administrative) and the Handbook's (in grey), read off the record above.
| Element | Value | In the record |
|---|---|---|
| DOI Name DOI name | 10.46243/jstj.2018.v3.i4.198 | doi |
| Referent Type referentType | Creation | referent |
| Referent Sub-Type referentSubType | JournalArticle — an article in a journal | type |
| Referent Name(s) referentName(s) | Effective Power Utilization Strategy of Fuel Cell System Using FSTP Sepic Inverter (PrincipalTitle, en) | titles |
| Basic Metadata basicMetadata | author: A. Arun Vikram author: R. Ram Kumar author: R. Navaneeth author: G. Gokulakrishnan publisher: Longman Publishers published: 2018-07-01 part of: Journal of Science & Technology · ISSN 2456-5660 · vol. 03 · no. 04 · pp. 20–31 language: en form: Digital · Visual · Language | agents, dates, container, language, structural_type, modes, characters |
| Referent Identifier(s) alternateIdentifier(s) | none besides the DOI | identifiers, relations (IsSameAs) |
| Registration Authority registrationAuthorityCode | Crossref — issued by Crossref (member 25296); held here as a copy | record.source_agency (our code, ra_doi_name, for names issued here once appointed) |
| Created Date issueDate | 2026-09-08 | record.registered (when the DOI name was first registered) |
| relatedIdentifiers | none needed — the descriptive metadata is in this record | container, relations (only where the descriptive metadata lives at another identifier) |
complete Every System Metadata element is here, with the basic metadata a journal article needs.
The System Metadata Declaration (JSON) · the Kernel Metadata Declaration (XML) · what each sub-type needs
History — the ledger
Every change to this DOI, in order, as it was recorded. Entries are only ever added, never changed or removed.
| # | When | What | By | Changes |
|---|---|---|---|---|
| 1 | 29 Sep 2026, 10:00 PM | register registered at Crossref; record read from api.crossref.org | Administrator (admin) | 98 fields set · sha256 9058d7c72230… |
| 2 | 29 Sep 2026, 11:59 PM | update record re-read from api.crossref.org | Administrator (admin) | container.titles.0.value: |
Machine-readable: the history as JSON, with the full record after each change.
