10.46243/jst.2022.v7.i01.pp136-165 registered
DESIGN &ANALYSIS OF MICRO INVERTER FOR PV PLANTS
Resolves to https://www.jst.org.in/index.php/pub/article/view/258
Held by Longman Publishers (India) · prefix 10.46243 live · DOI address https://doi.org/10.46243/jst.2022.v7.i01.pp136-165
Registered 29 Sep 2026 via crossref · record version 2 · last change 29 Sep 2026, 11:59 PM · record sha256 c22408d6641d949d…
Resolve ⬇ Record (JSON) ⬇ Kernel Metadata Declaration (XML) Compare with Crossref Cite (APA · BibTeX · RIS · CSL)
Also as schema.org JSON-LD · Turtle · RDF/XML · DataCite XML · Crossref UNIXREF · Crossref UNIXSD — the formats of the DOI content-negotiation service, from this record (which carries what).
What the DOI identifies
JournalArticle — an article in a journal · Digital · Visual · en
DESIGN &ANALYSIS OF MICRO INVERTER FOR PV PLANTS (PrincipalTitle · en)
Published 2023-07-26
Part of Journal of Science & Technology · ISSN 2456-5660 · volume 7 · issue 1 · pages 136–165
Agents
- Ms.Shaik Neelafar Ms.Shaik Neelafar (author)
- Longman Publishers (publisher)
Identifiers DOI 10.46243/jst.2022.v7.i01.pp136-165
Abstract · en
Renewable energy sources are obviously accepted as clean energy sources of future. The solar energy is the most popular among other renewable energy sources in all over the world. Many studies are performed on photovoltaic (PVs) and solar energy systems. Inverter is the most important power converter section of photovoltaic systems in terms of efficiency in changing weather conditions. This study presents the design and analysis of a micro inverter for PV systems. The proposed micro inverter is designed by using MATLAB Simulink software, and the control algorithms are implemented according to Incremental Conductance method. It consists of isolated boost converter with Maximum Power Point Tracking (MPPT) and H-bridge inverter with PI controller. The reaction of system has been observed under changing irradiation conditions. The implemented micro inverter has compensated the irradiation changes at boost converter stage, and dc-ac conversion process is performed regarding to the designed PI controller. The dc bus voltage is increased to around 300V, and the HF transformer is used to increase inverter input voltage to 420V. The output of inverter is generated with the support of PI controller to track 220Vrms line voltage. The THD rates for both voltage and current are measured at 0.51% in FFT spectrum, and the overall power of the micro inverter is supplied around 315W
System metadata — ISO 26324:2025, Annex B · DOI Handbook 10.1
Each element by the standard's name (Annex B: reference elements, then administrative) and the Handbook's (in grey), read off the record above.
| Element | Value | In the record |
|---|---|---|
| DOI Name DOI name | 10.46243/jst.2022.v7.i01.pp136-165 | doi |
| Referent Type referentType | Creation | referent |
| Referent Sub-Type referentSubType | JournalArticle — an article in a journal | type |
| Referent Name(s) referentName(s) | DESIGN &ANALYSIS OF MICRO INVERTER FOR PV PLANTS (PrincipalTitle, en) | titles |
| Basic Metadata basicMetadata | author: Ms.Shaik Neelafar Ms.Shaik Neelafar publisher: Longman Publishers published: 2023-07-26 part of: Journal of Science & Technology · ISSN 2456-5660 · vol. 7 · no. 1 · pp. 136–165 language: en form: Digital · Visual · Language | agents, dates, container, language, structural_type, modes, characters |
| Referent Identifier(s) alternateIdentifier(s) | none besides the DOI | identifiers, relations (IsSameAs) |
| Registration Authority registrationAuthorityCode | Crossref — issued by Crossref (member 25296); held here as a copy | record.source_agency (our code, ra_doi_name, for names issued here once appointed) |
| Created Date issueDate | 2024-02-16 | record.registered (when the DOI name was first registered) |
| relatedIdentifiers | none needed — the descriptive metadata is in this record | container, relations (only where the descriptive metadata lives at another identifier) |
complete Every System Metadata element is here, with the basic metadata a journal article needs.
The System Metadata Declaration (JSON) · the Kernel Metadata Declaration (XML) · what each sub-type needs
Cited by — in this registry
No record held in this registry cites this DOI.
Counts only records held in this registry; a citation from a work held elsewhere is not seen here. The list as JSON
References with DOIs
The record lists 18 references; 17 carry a DOI.
| # | Reference | DOI | Held here |
|---|---|---|---|
| 1 | ref1 G. K. Singh, Solar power generation by PV (photovoltaic) technology: A review, Energy, vol. 53, pp. 113, May. 2013 | 10.1016/j.energy.2013.02.057 | not held here |
| 3 | ref3 A. M¨aki and S. Valkealahti, Power losses in log string and parallel connected short strings of series-connected silicon-based photovoltaic modules due to partial shading conditio… | 10.1109/tec.2011.2175928 | not held here |
| 4 | ref4 N. D. Kaushinka and A. K. Rai, An investigation of mismatch losses in solar photovoltaic cell networks, Energy vol. 32, no. 5, pp. 755-759. May 2007 | 10.1016/j.energy.2006.06.017 | not held here |
| 5 | ref5 R. C. N. Pilawa-Podgurski and D. J. Perreault, Submodule integrated distributed maximum power point tracking for solar photovoltaic applications, IEEE Trans. Power Electron. vol. … | 10.1109/tpel.2012.2220861 | not held here |
| 6 | ref6 N. Sukesh, M. Pahlevaninezhad and P. K. Jain, An investigation of mismatch losses in solar photovoltaic cell networks, IEEE Transactionson Industrial Electronics, vol. 61, no. 4, … | 10.1109/tie.2013.2263778 | not held here |
| 7 | ref7 T. Shimizu, K. Wada, and N. Nakamura, Flyback-Type Single-Phase Utility Interactive Inverter With Power Pulsation Decoupling on the DC Input for an AC Photovoltaic Module System, … | 10.1109/tpel.2006.880247 | not held here |
| 8 | ref8 T. Shimizu, K. Wada, and N. Nakamura, A flyback-type single phase utility interactive inverter with low-frequency ripple current reduction on the DC input for an AC photovoltaic m… | 10.1109/psec.2002.1022385 | not held here |
| 9 | ref9 N. Kasa, T. Iida, and L. Chen, Flyback inverter controlled by sensorless current MPPT for photovoltaic power system, IEEE Trans. Ind. Electron., vol. 52, no. 4, pp. 11451152, Aug.… | 10.1109/tie.2005.851602 | not held here |
| 10 | ref10 M. A. Rezaei, K. J. Lee and A. Q. Huang. A High-Efficiency Flyback Micro-inverter With a New Adaptive Snubber for Photovoltaic Applications, IEEE Trans. on Power Electron., vol. 3… | 10.1109/tpel.2015.2407405 | not held here |
| 11 | ref11 M. Pahlevani, S. Eren, J. M. Guerrero and P. Jain, A Hybrid Estimator for Active/Reactive Power Control of Single-Phase Distributed Generation Systems With Energy Storage, in IEEE… | 10.1109/tpel.2015.2453350 | not held here |
| 12 | ref12 S. Eren, M. Pahlevaninezhad, A. Bakhshai and P. K. Jain, Composite Nonlinear Feedback Control and Stability Analysis of a Grid-Connected Voltage Source Inverter With LCL Filter, i… | 10.1109/tie.2012.2225399 | not held here |
| 13 | ref13 R. Hermann and A. Krener. Nonlinear controllability and observability, IEEE Transactions on Automatic Control, vol. 22, no. 5, pp. 728-740 Oct | 10.1109/tac.1977.1101601 | not held here |
| 14 | ref14 M. Pahlevaninezhad, S. Eren, H. Pahlevani, I. Askarian and S. Bagawade. Digital Current Sensorless Control of Current-Driven Full-Bridge DC/DC Converters, IEEE Trans. on Power Ele… | 10.1109/tpel.2017.2688479 | not held here |
| 15 | ref15 S. Diop and M. Wang, Equivalence between algebraic observability and local generic observability, Proc. 32nd IEEE Conf. on Decis. Control,1993 pp. 2864-2865 | 10.1109/cdc.1993.325718 | not held here |
| 16 | ref16 I. Askarian, S. Eren, M. Pahlevani and A. Knight, Digital Real-Time Harmonic Estimator for Power Converters in Future Micro-Grids, IEEETransactions on Smart Grid, June 2017 | 10.1109/tsg.2017.2711016 | not held here |
| 17 | ref17 M. Pahlevani, S. Pan, S. Eren, A. Bakhshai and P. Jain, An Adaptive Nonlinear Current Observer for Boost PFC AC/DC Converters, in IEEETransactions on Industrial Electronics, vol. … | 10.1109/tie.2014.2316216 | not held here |
| 18 | ref18 S. Eren, M. Pahlevani, A. Bakhshai and P. Jain, A Digital Current Control Technique for Grid-Connected AC/DC Converters Used for Energy Storage Systems, in IEEE Transactions on Po… | 10.1109/tpel.2016.2582901 | not held here |
Relations
The record states no relation, and no record held here states one with this DOI.
Funding
The record names no funder.
Each funder's page lists every work held here that names it. ROR IDs open at ror.org; Funder Registry IDs resolve at doi.org.
History — the ledger
Every change to this DOI, in order, as it was recorded. Entries are only ever added, never changed or removed.
| # | When | What | By | Changes |
|---|---|---|---|---|
| 1 | 29 Sep 2026, 10:00 PM | register registered at Crossref; record read from api.crossref.org | Administrator (admin) | 107 fields set · sha256 8f2f2bf50707… |
| 2 | 29 Sep 2026, 11:59 PM | update record re-read from api.crossref.org | Administrator (admin) | container.titles.0.value: titles.0.value: |
Machine-readable: the history as JSON, with the full record after each change.
Changes made at Crossref through DOI Doctor
Every deposit Smart Scholars' DOI Doctor made for this DOI, oldest first, with Crossref's own answer. Each fingerprint is the SHA-256 of its entry and of the fingerprint before it, so a change to any earlier entry changes every fingerprint after it.
| When | What changed | Crossref | Fingerprint |
|---|---|---|---|
| 11 Sep 2026, 05:18 | Address updated from https://jst.org.in/index.php/pub/article/view/258/225 to https://www.jst.org.in/index.php/pub/article/view/258 | ● accepted by Crossref | cf94bd0e8cae… |
| 13 Sep 2026, 01:40 | Read back: the DOI resolves to the new address | ● confirmed | 6dfba223324b… |
| 07 Oct 2026, 07:37 | Metadata completed abstract (214 words) · licence | ● accepted by Crossref | aab2ed6c04ff… |
| 07 Oct 2026, 08:47 | Read back: Crossref's record shows it | ● confirmed | 7c1dc9c77f48… |
4 entries · the last fingerprint 7c1dc9c77f481d93ae5b05527869743674f70fa717e4f00f3e9fd9bd5a9963f0 · the history as JSON, each entry with the fingerprint before it, to check them yourself.



