Cite this DOI
10.46243/jst.2022.v7.i01.pp97-102 · A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug
APA (7th edition)
Sachin S. Garad, S. S. G. (2022). A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug. *Journal of Science & Technology*, *7*(Special 1), 97–102. https://doi.org/10.46243/jst.2022.v7.i01.pp97-102
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{sachinsgarad2022simple,
author = {Sachin S. Garad, Sachin S. Garad},
title = {{A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug}},
journal = {Journal of Science \& Technology},
year = {2022},
month = {may},
volume = {7},
number = {Special 1},
pages = {97--102},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jst.2022.v7.i01.pp97-102},
url = {https://doi.org/10.46243/jst.2022.v7.i01.pp97-102},
language = {en},
abstract = {A simple, economical, user -friendly, precise, accurate, robust, rugged and linear analyt ical method developed and validated for estimation (Assay) of Aceclofenac in Active Pharmaceutical Ingredients or bulk drug form.Isocratic HPLC method developed, flow rate is 1.5 ml/min, and column used Hemochrom C18 Intsil (150mm X 4.6 mm X 5 µm), Column temperature used is 25ºC. Mobile phase used is made from 50 volume of buffer consist of 0.1 \% orthophosphoric acid and 50 volumes of organic phase consist of 90\% Acetonitrile. The UV detection wavelength is 275 nm. Linearity of the method was observed 50 µ g/ml to 150 µg/ml. The retention time of Aceclofenac is ≈ 6.0 minute. This method was validated as per ICH guideline. (1) This method is very user -friendly and can be used for estimation of Aceclofenac in Active Pharmaceutical Ingredients and Bulk drug for m because Analytical method validation of this method is successfully achieved in present study}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug AU - Sachin S. Garad, Sachin S. Garad JO - Journal of Science & Technology PY - 2022 DA - 2022/05/22/ VL - 7 IS - Special 1 SP - 97 EP - 102 PB - Longman Publishers SN - 2456-5660 LA - en AB - A simple, economical, user -friendly, precise, accurate, robust, rugged and linear analyt ical method developed and validated for estimation (Assay) of Aceclofenac in Active Pharmaceutical Ingredients or bulk drug form.Isocratic HPLC method developed, flow rate is 1.5 ml/min, and column used Hemochrom C18 Intsil (150mm X 4.6 mm X 5 µm), Column temperature used is 25ºC. Mobile phase used is made from 50 volume of buffer consist of 0.1 % orthophosphoric acid and 50 volumes of organic phase consist of 90% Acetonitrile. The UV detection wavelength is 275 nm. Linearity of the method was observed 50 µ g/ml to 150 µg/ml. The retention time of Aceclofenac is ≈ 6.0 minute. This method was validated as per ICH guideline. (1) This method is very user -friendly and can be used for estimation of Aceclofenac in Active Pharmaceutical Ingredients and Bulk drug for m because Analytical method validation of this method is successfully achieved in present study DO - 10.46243/jst.2022.v7.i01.pp97-102 UR - https://doi.org/10.46243/jst.2022.v7.i01.pp97-102 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jst.2022.v7.i01.pp97-102",
"DOI": "10.46243/jst.2022.v7.i01.pp97-102",
"URL": "https://doi.org/10.46243/jst.2022.v7.i01.pp97-102",
"title": "A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "Sachin S. Garad",
"given": "Sachin S. Garad"
}
],
"issued": {
"date-parts": [
[
2022,
5,
22
]
]
},
"volume": "7",
"issue": "Special 1",
"page": "97-102",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "A simple, economical, user -friendly, precise, accurate, robust, rugged and linear analyt ical method developed and validated for estimation (Assay) of Aceclofenac in Active Pharmaceutical Ingredients or bulk drug form.Isocratic HPLC method developed, flow rate is 1.5 ml/min, and column used Hemochrom C18 Intsil (150mm X 4.6 mm X 5 µm), Column temperature used is 25ºC. Mobile phase used is made from 50 volume of buffer consist of 0.1 % orthophosphoric acid and 50 volumes of organic phase consist of 90% Acetonitrile. The UV detection wavelength is 275 nm. Linearity of the method was observed 50 µ g/ml to 150 µg/ml. The retention time of Aceclofenac is ≈ 6.0 minute. This method was validated as per ICH guideline. (1) This method is very user -friendly and can be used for estimation of Aceclofenac in Active Pharmaceutical Ingredients and Bulk drug for m because Analytical method validation of this method is successfully achieved in present study",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.