{
    "ok": true,
    "doi": "10.46243/jstj.2017.v2.i4.211",
    "doi_display": "10.46243/jstj.2017.v2.i4.211",
    "doi_url": "https://doi.org/10.46243/jstj.2017.v2.i4.211",
    "state": "registered",
    "url": "https://www.jst.org.in/index.php/pub/article/view/211",
    "title": "Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement",
    "version": 2,
    "registered_via": "crossref",
    "prefix": {
        "prefix": "10.46243",
        "status": "live"
    },
    "registrant": {
        "name": "Longman Publishers",
        "kind": "publisher",
        "country": "India"
    },
    "reserved_at": null,
    "registered_at": "2026-09-29 22:00:37",
    "updated_at": "2026-09-29 23:59:57",
    "withdrawn_at": null,
    "withdrawn_reason": null,
    "record": {
        "format": "smartscholars-doi-metadata/1.0",
        "doi": "10.46243/jstj.2017.v2.i4.211",
        "referent": "Creation",
        "type": "JournalArticle",
        "structural_type": "Digital",
        "modes": [
            "Visual"
        ],
        "characters": [
            "Language"
        ],
        "titles": [
            {
                "value": "Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement",
                "type": "PrincipalTitle",
                "lang": "en"
            }
        ],
        "identifiers": [
            {
                "type": "DOI",
                "value": "10.46243/jstj.2017.v2.i4.211"
            }
        ],
        "agents": [
            {
                "role": "author",
                "name": {
                    "given": "S. Balaji",
                    "family": "Reddy"
                },
                "sequence": "first"
            },
            {
                "role": "author",
                "name": {
                    "given": "M.V.Raghavendra",
                    "family": "Reddy"
                },
                "sequence": "additional"
            },
            {
                "role": "publisher",
                "name": {
                    "org": "Longman Publishers"
                }
            }
        ],
        "dates": {
            "published": "2017-07-13",
            "date_type": "PublicationDate",
            "online": "2017-07-13"
        },
        "language": "en",
        "container": {
            "type": "Journal",
            "titles": [
                {
                    "value": "Journal of Science & Technology",
                    "type": "PrincipalTitle"
                }
            ],
            "identifiers": [
                {
                    "type": "ISSN",
                    "value": "2456-5660",
                    "medium": "electronic"
                }
            ],
            "volume": "02",
            "issue": "04",
            "pages": {
                "first": "41",
                "last": "45"
            }
        },
        "links": [
            {
                "url": "https://www.jst.org.in/index.php/pub/article/view/211",
                "return_type": "text/html",
                "primary": true
            },
            {
                "url": "https://www.jst.org.in/index.php/pub/article/download/211/188",
                "purpose": "text-mining",
                "return_type": "application/pdf"
            },
            {
                "url": "https://www.jst.org.in/index.php/pub/article/download/211/3527",
                "purpose": "text-mining",
                "return_type": "application/xml"
            },
            {
                "url": "https://www.jst.org.in/index.php/pub/article/view/211/188",
                "purpose": "similarity-checking"
            }
        ],
        "abstract": {
            "value": "Power Quality means maintaining purely sinusoidal current wave form in phase with a purely sinusoidal voltage wave form throughout in a power system. Due to intensive use of power converters and other non linear loads in industries, an increasing deterioration of the power system voltage and current waveforms has been observed. The most important cause for degrading power quality are harmonic distortion and low power factor. Conventionally, Passive filters have been used as a solution to solve harmonic current problems, but they are not capable of mitigating the low power factor problems. So an improved method of Active Power Filter (APF) used to eliminate the disturbances in current. This paper examines the control of Shunt Active Power Filter (SAPF) with Synchronous Reference Frame (SRF) detection method. Here a twelve pulse diode bridge rectifier will be the non linear load and the switching frequency is set to 10 kHz. Simulation analyses are done using Matlab/Simulink software",
            "lang": "en"
        },
        "license": {
            "url": "https://creativecommons.org/licenses/by/4.0/",
            "start": "2017-07-13",
            "applies_to": "vor"
        },
        "references": [
            {
                "key": "ref1",
                "doi": "10.1109/ias.1990.152323",
                "unstructured": "H. Fujita, and H. Akagi, \"A practical approach to harmonic compensation inpower systems-series connection of passive and active filters,\" in Industry Applications Society Annual Meeting, 1990., Conference Record of the 1990 IEEE, 1990, pp. 1107-1112 voL2"
            },
            {
                "key": "ref2",
                "doi": "10.1109/ipemc.2006.297165",
                "unstructured": "W. Liqiao, and W. Weiyang, \"Shunt Active Power Filter with Sample Time Staggered Space Vector Modulation Based Cascade Multilevel Converters,\" in Power Electronics and Motion Control Conference, 2006. IPEMC 2006. CESIIEEE 5th International, 2006, pp. 1-5"
            },
            {
                "key": "ref3",
                "doi": "10.1109/icit.2013.6505789",
                "unstructured": "W. Lenwari, \"Optimized design of modified proportional ­ resonant controller for current control of active filters,\" in Industrial Technology (ICIT), 2013 IEEE International Conference on, 2013, pp. 894-899"
            },
            {
                "key": "ref4",
                "doi": "10.1109/tie.2012.2206335",
                "unstructured": "H. Sepahvand, L. Jingsheng, M. Ferdowsi, and K. A. Corzine, \"Capacitor Voltage Regulation in Single-DC-Source Cascaded H-Bridge Multilevel Converters Using Phase-Shift Modulation,\" Industrial Electronics, IEEE Transactions on, vol. 60,n o. 9,pp. 3619-3626,2013"
            },
            {
                "key": "ref5",
                "doi": "10.1109/pedstc.2010.5471777",
                "unstructured": "A. Kahrobaeian, and S. Farhangi, \"Stationary frame current control of single phase grid connected PV inverters.\" pp. 435- 438"
            },
            {
                "key": "ref6",
                "doi": "10.1109/tpel.2009.2036012",
                "unstructured": "D. De, and V. Ramanarayanan, \"A Proportional+Multiresonant Controller for Three-Phase Four-Wire High-Frequency Link Inverter,\" Power Electronics, IEEE Transactions on, vol. 25, no. 4, pp. 899-906,2010"
            },
            {
                "key": "ref7",
                "doi": "10.1109/28.536875",
                "unstructured": "P. Fang Zheng, L. Jih-Sheng, J. W. McKeever, and J. VanCoevering, \"A multilevel voltage-source inverter with separate DC sources for static V Ar generation,\" Industry Applications, IEEE Transactions on, vol. 32, no. 5, pp. 1130-1138, 1996"
            },
            {
                "key": "ref8",
                "doi": "10.1109/ipemc.2006.297165",
                "unstructured": "W. Liqiao, and W. Weiyang, \"Shunt Active Power Filter with Sample Time Staggered Space Vector Modulation Based Cascade Multilevel Converters,\" in Power Electronics and Motion Control Conference, 2006. IPEMC 2006. CESIIEEE 5th International, 2006, pp. 1-5"
            },
            {
                "key": "ref9",
                "doi": "10.1109/sceecs.2014.6804463",
                "unstructured": "P. Orner, 1. Kumar, and B. S. Su �jan, \"C omparison of multicarrier PWM techniques for cascaded H-bridge inverter,\" in Electrical, Electronics and Computer Science (SCEECS), 2014 IEEE Students' Conference on, 2014, pp. 1-6"
            },
            {
                "key": "ref10",
                "unstructured": "S. Mohammadi, H. R Mosaddegh, and M. Y ousefian, \"Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach,\" Journal of Electrical and Computer Engineering Innovations, vol. 1, no. 2, pp. 83-88,12/30,2013"
            },
            {
                "key": "ref11",
                "doi": "10.1049/iet-pel.2010.0137",
                "unstructured": "M. Odavic, V. Biagini, P. Zanchetta, M. Sumner, and M. Degano, \"Onesample-period-ahead predictive current control for high-performance active shunt power filters,\" Power Electronics, lET, vol. 4, no. 4, pp. 414-423, 2011"
            },
            {
                "key": "ref12",
                "doi": "10.1109/tie.2007.894790",
                "unstructured": "R. Grino, R. Cardoner, C. Costa, x, R, and E. Fossas, \"Digital Repetitive Control of a Three-Phase Four-Wire Shunt Active Filter,\" Industrial Electronics, IEEE Transactions on, vol. 54, no.3,pp.1495-1503,2007"
            },
            {
                "key": "ref13",
                "doi": "10.1109/28.855974",
                "unstructured": "M. Sedighy, S. B. Dewan, and F. P. Dawson, \"A robust digital current control method for active power filters,\" Industry Applications, IEEE Transactions on, vol. 36, no. 4, pp. 1158-1164,2000"
            },
            {
                "key": "ref14",
                "doi": "10.1109/tpel.2006.890002",
                "unstructured": "L. Yun Wei, F. Blaabjerg, D. M. Vilathgamuwa, and L. Poh Chiang, \"Design and Comparison of High Performance Stationary-Frame Controllers for DVR Implementation,\" Power Electronics, IE EE Transactions on, vol. 22, no. 2, pp. 602-612, 2007"
            },
            {
                "key": "ref15",
                "doi": "10.1109/icit.2013.6505789",
                "unstructured": "W. Lenwari, \"Optimized design of modified proportionalresonant controller for current control of active filters,\" in Industrial Technology (ICIT), 2013 IEEE International Conference on, 2013, pp. 894-899"
            }
        ],
        "record": {
            "registrant": "Longman Publishers",
            "registered": "2026-09-08",
            "updated": "2026-09-20",
            "issue_number": 1,
            "source": "crossref-api",
            "source_agency": "Crossref (member 25296)"
        }
    },
    "record_sha256": "4c028049accac2e1a74ef20bcbc0539b4a2003d5d102b47e34e2e3849f442f23",
    "handle": {
        "synced_at": "2026-10-01 18:13:42",
        "url": "https://www.jst.org.in/index.php/pub/article/view/211"
    },
    "links": {
        "record_page": "https://registry.smartscholars.in/record.php?doi=10.46243%2Fjstj.2017.v2.i4.211",
        "system_metadata": "https://registry.smartscholars.in/resolve.php?doi=10.46243%2Fjstj.2017.v2.i4.211&as=system",
        "history": "https://registry.smartscholars.in/api.php?action=history&doi=10.46243%2Fjstj.2017.v2.i4.211",
        "kernel_xml": "https://registry.smartscholars.in/resolve.php?doi=10.46243%2Fjstj.2017.v2.i4.211&as=xml"
    }
}