    "ok": true,
    "doi": "10.46243/jst.2022.v7.i02.pp139-145",
    "doi_display": "10.46243/jst.2022.v7.i02.pp139-145",
    "doi_url": "https://doi.org/10.46243/jst.2022.v7.i02.pp139-145",
    "state": "registered",
    "url": "https://www.jst.org.in/index.php/pub/article/view/410",
    "title": "FLUID-STRUCTURE INTERACTION IN WATER TANKS: DYNAMIC ASSESSMENT",
    "version": 2,
    "registered_via": "crossref",
    "prefix": {
        "prefix": "10.46243",
        "status": "live"
    },
    "registrant": {
        "name": "Longman Publishers",
        "kind": "publisher",
        "country": "India"
    },
    "reserved_at": null,
    "registered_at": "2026-09-29 22:00:27",
    "updated_at": "2026-09-29 23:59:46",
    "withdrawn_at": null,
    "withdrawn_reason": null,
    "record": {
        "format": "smartscholars-doi-metadata/1.0",
        "doi": "10.46243/jst.2022.v7.i02.pp139-145",
        "referent": "Creation",
        "type": "JournalArticle",
        "structural_type": "Digital",
        "modes": [
            "Visual"
        ],
        "characters": [
            "Language"
        ],
        "titles": [
            {
                "value": "FLUID-STRUCTURE INTERACTION IN WATER TANKS: DYNAMIC ASSESSMENT",
                "type": "PrincipalTitle",
                "lang": "en"
            }
        ],
        "identifiers": [
            {
                "type": "DOI",
                "value": "10.46243/jst.2022.v7.i02.pp139-145"
            }
        ],
        "agents": [
            {
                "role": "author",
                "name": {
                    "given": "Mr.K.A.S.V.R.Sai Phani Kumar",
                    "family": "Mr.K.A.S.V.R.Sai Phani Kumar"
                },
                "sequence": "first"
            },
            {
                "role": "publisher",
                "name": {
                    "org": "Longman Publishers"
                }
            }
        ],
        "dates": {
            "published": "2022-07-03",
            "date_type": "PublicationDate",
            "online": "2022-07-03"
        },
        "language": "en",
        "container": {
            "type": "Journal",
            "titles": [
                {
                    "value": "Journal of Science & Technology",
                    "type": "PrincipalTitle"
                }
            ],
            "identifiers": [
                {
                    "type": "ISSN",
                    "value": "2456-5660",
                    "medium": "electronic"
                }
            ],
            "volume": "7",
            "issue": "2",
            "pages": {
                "first": "139",
                "last": "145"
            }
        },
        "links": [
            {
                "url": "https://www.jst.org.in/index.php/pub/article/view/410",
                "return_type": "text/html",
                "primary": true
            },
            {
                "url": "https://www.jst.org.in/index.php/pub/article/download/410/363",
                "purpose": "text-mining",
                "return_type": "application/pdf"
            },
            {
                "url": "https://www.jst.org.in/index.php/pub/article/download/410/2225",
                "purpose": "text-mining",
                "return_type": "application/xml"
            },
            {
                "url": "https://jst.org.in/admin/uploads/JST_MAR_2022.docx.pdf",
                "purpose": "similarity-checking"
            }
        ],
        "abstract": {
            "value": "Due to increased population and growth of cities, the number of raised water tanks servicing the demand urban \\swater system is on the rise. As it has been indicated in the Iranian code of practise for Earthquake /2800 due \\sof the necessity of sanitation and hygiene water tanks have been recognised as vital constructions during the unforeseen occurrences such as earthquake. There is a high anticipation not to observe any phase out for their serviceability following the earthquake. Because of the presence of fluid with various behavioural features of structures containing it Because the most part of mass of tanks are posi tioned in a great distance from their foundation, the behaviour of these sorts of structures in comparing with conventional structures are more sophisticated. In this study, cylindrical concrete water tanks, which feature a central shaft, have been examined with consideration the influence of the structure’s contact with water via accurate execution of boundary constraints on the interface between fluid and structure. Also considering the volume of water in the tank and their response under recorded acceler ation of varied earthquakes utilising finite element approach. The findings were then compared with proposed ways by Iranian code /2800, which shows a significant variation between the approaches given",
            "lang": "en"
        },
        "license": {
            "url": "https://creativecommons.org/licenses/by/4.0/",
            "start": "2022-07-03",
            "applies_to": "vor"
        },
        "references": [
            {
                "key": "ref1",
                "doi": "10.1785/bssa0530020381",
                "unstructured": "Housner, G.W. (1963). The Dynamic Behavior of Water Tanks. Bulletin of Seismological Society of America 53, 381- 387. Hamdi, M.E. (1978). A Displacements for the analysis of vibrations of coupled fluid- structures systems. Int. J. Num. Meth., 13, 139-150"
            },
            {
                "key": "ref2",
                "doi": "10.1002/nme.1620191105",
                "unstructured": "Wilson, E.L. and Khalvati.M. (1983). Finite Elements for Dynamic Analysis of fluid- structure systems. Int. J. Num. Meth. En 19, 1657-1668"
            },
            {
                "key": "ref3",
                "doi": "10.1016/0045-7949(85)90205-6",
                "unstructured": "Sharan, S.K., Gladwell, G.M. (1985). A general method for the dynamic response analysis of fluid-structures systems. Comput and structures, 21:5, 937-943"
            },
            {
                "key": "ref4",
                "doi": "10.1016/0045-7949(85)90226-3",
                "unstructured": "Olson, L.G., Bathe, K.J. (1985). Analysis of fluid-structure interaction. A direct symmetric coupled formulation based on the fl velocity potential. Comput. Struct., 21:1/2, 21-32. Ministry of Housing and urban development (Iran), (2006). Iranian code for seismic resistant design of building, (in Persian)"
            }
        ],
        "record": {
            "registrant": "Longman Publishers",
            "registered": "2024-02-16",
            "updated": "2026-09-17",
            "issue_number": 1,
            "source": "crossref-api",
            "source_agency": "Crossref (member 25296)"
        }
    },
    "record_sha256": "3138a1386e906ad1928fbe0a82ecd4c52184a357c6146a231bb0e4f289cbde04",
    "handle": {
        "synced_at": "2026-10-01 18:12:34",
        "url": "https://www.jst.org.in/index.php/pub/article/view/410"
    },
    "links": {
        "record_page": "https://registry.smartscholars.in/record.php?doi=10.46243%2Fjst.2022.v7.i02.pp139-145",
        "system_metadata": "https://registry.smartscholars.in/resolve.php?doi=10.46243%2Fjst.2022.v7.i02.pp139-145&as=system",
        "history": "https://registry.smartscholars.in/api.php?action=history&doi=10.46243%2Fjst.2022.v7.i02.pp139-145",
        "kernel_xml": "https://registry.smartscholars.in/resolve.php?doi=10.46243%2Fjst.2022.v7.i02.pp139-145&as=xml"
    }
}