Skip to content
Smart Scholars🛡 Scholar Shield🏛 Research Integrity Desk🧩 Portfolio Console📰 Journals🔧 DOI MembersTools🔎 Journal AuditGI GetIndexedDr DOI Doctor

Cite this DOI

10.46243/jstj.2019.v4.i4.97 · Analysis and Control Of Grid Connected Multi Terminal HVDC System

APA (7th edition)

G.Balaji, & K.S.Srikanth (2019). Analysis and Control Of Grid Connected Multi Terminal HVDC System. *Journal of Science & Technology*, *04*(04), 01–08. https://doi.org/10.46243/jstj.2019.v4.i4.97

⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.

BibTeX

@article{gbalaji2019analysis,
  author    = {G.Balaji and K.S.Srikanth},
  title     = {{Analysis and Control Of Grid Connected Multi Terminal HVDC System}},
  journal   = {Journal of Science \& Technology},
  year      = {2019},
  month     = {jul},
  volume    = {04},
  number    = {04},
  pages     = {01--08},
  publisher = {Longman Publishers},
  issn      = {2456-5660},
  doi       = {10.46243/jstj.2019.v4.i4.97},
  url       = {https://doi.org/10.46243/jstj.2019.v4.i4.97},
  language  = {en},
  abstract  = {When connecting a wind park (WP) to the main grid (MG) by way of an HVDC Light transmission system, the WPbecomes decoupled from the MG, which results in several technical and economical benefits, on a variety of aspects, for transmission system operators (TSOs), WP developers and WTG manufacturers. Perhaps most important for TSOs is that an HVDC-Light connected WP becomes comparable to a normal power plant; the MG-side HVDC Light converter can be directly connected to a control or power dispatch center. A desirable consequence is also that AC faults appearing in the WP or MG grid will not be propagated by the HVDC Light transmission system, which has several desirable consequences such as possibly reduced mechanical stresses on the WTGs.This paper presents operation and control strategies of multi-terminal HVDC transmission system (MTDC) using voltage source converters (VSCs) for integrating large offshore wind farms. The framework and operation principles of the proposed system are described and control strategies for coordinating various VSCs are proposed. DC voltage control based on the DC voltage-current (V-I) droop characteristic of grid side converters is implemented, to ensure stable system operation and flexible power dispatch between various onshore AC grids. To validate the performance of the proposed control strategies, a typical four terminal MTDC networks, which connecting two offshore wind farms with two onshore AC grids, is established in PSCAD/EMTEC. Simulation results under normal and abnormal operation conditions verify the satisfactory performance of the proposed control strategy and accuracy of the theoretical analysis.}
}

⬇ .bib

RIS (EndNote, Zotero, Mendeley)

TY  - JOUR
TI  - Analysis and Control Of Grid Connected Multi Terminal HVDC System
AU  - G.Balaji
AU  - K.S.Srikanth
JO  - Journal of Science & Technology
PY  - 2019
DA  - 2019/07/01/
VL  - 04
IS  - 04
SP  - 01
EP  - 08
PB  - Longman Publishers
SN  - 2456-5660
LA  - en
AB  - When connecting a wind park (WP) to the main grid (MG) by way of an HVDC Light transmission system, the WPbecomes decoupled from the MG, which results in several technical and economical benefits, on a variety of aspects, for transmission system operators (TSOs), WP developers and WTG manufacturers. Perhaps most important for TSOs is that an HVDC-Light connected WP becomes comparable to a normal power plant; the MG-side HVDC Light converter can be directly connected to a control or power dispatch center. A desirable consequence is also that AC faults appearing in the WP or MG grid will not be propagated by the HVDC Light transmission system, which has several desirable consequences such as possibly reduced mechanical stresses on the WTGs.This paper presents operation and control strategies of multi-terminal HVDC transmission system (MTDC) using voltage source converters (VSCs) for integrating large offshore wind farms. The framework and operation principles of the proposed system are described and control strategies for coordinating various VSCs are proposed. DC voltage control based on the DC voltage-current (V-I) droop characteristic of grid side converters is implemented, to ensure stable system operation and flexible power dispatch between various onshore AC grids. To validate the performance of the proposed control strategies, a typical four terminal MTDC networks, which connecting two offshore wind farms with two onshore AC grids, is established in PSCAD/EMTEC. Simulation results under normal and abnormal operation conditions verify the satisfactory performance of the proposed control strategy and accuracy of the theoretical analysis.
DO  - 10.46243/jstj.2019.v4.i4.97
UR  - https://doi.org/10.46243/jstj.2019.v4.i4.97
ER  -

⬇ .ris

CSL-JSON

{
    "type": "article-journal",
    "id": "10.46243/jstj.2019.v4.i4.97",
    "DOI": "10.46243/jstj.2019.v4.i4.97",
    "URL": "https://doi.org/10.46243/jstj.2019.v4.i4.97",
    "title": "Analysis and Control Of Grid Connected Multi Terminal HVDC System",
    "source": "Smart Scholars Registry",
    "container-title": "Journal of Science & Technology",
    "author": [
        {
            "family": "G.Balaji"
        },
        {
            "family": "K.S.Srikanth"
        }
    ],
    "issued": {
        "date-parts": [
            [
                2019,
                7,
                1
            ]
        ]
    },
    "volume": "04",
    "issue": "04",
    "page": "01-08",
    "publisher": "Longman Publishers",
    "language": "en",
    "abstract": "When connecting a wind park (WP) to the main grid (MG) by way of an HVDC Light transmission system, the WPbecomes decoupled from the MG, which results in several technical and economical benefits, on a variety of aspects, for transmission system operators (TSOs), WP developers and WTG manufacturers. Perhaps most important for TSOs is that an HVDC-Light connected WP becomes comparable to a normal power plant; the MG-side HVDC Light converter can be directly connected to a control or power dispatch center. A desirable consequence is also that AC faults appearing in the WP or MG grid will not be propagated by the HVDC Light transmission system, which has several desirable consequences such as possibly reduced mechanical stresses on the WTGs.This paper presents operation and control strategies of multi-terminal HVDC transmission system (MTDC) using voltage source converters (VSCs) for integrating large offshore wind farms. The framework and operation principles of the proposed system are described and control strategies for coordinating various VSCs are proposed. DC voltage control based on the DC voltage-current (V-I) droop characteristic of grid side converters is implemented, to ensure stable system operation and flexible power dispatch between various onshore AC grids. To validate the performance of the proposed control strategies, a typical four terminal MTDC networks, which connecting two offshore wind farms with two onshore AC grids, is established in PSCAD/EMTEC. Simulation results under normal and abnormal operation conditions verify the satisfactory performance of the proposed control strategy and accuracy of the theoretical analysis.",
    "ISSN": "2456-5660"
}

⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.

From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjstj.2019.v4.i4.97 gives all four in one JSON answer.

Share this page

Share this page

Ask AI about this page

Everything Smart Scholars runs

Nine sites, one account. A journal starts at the audit; an author starts at Scholar Shield.

What we do: DOIs registered from what a journal already has · Crossref records completed — references, abstracts, licences, ORCID iDs, affiliations and ROR IDs, funding · DOIs that resolve · articles preserved · journals rated on the public record · see everything we do →

Book a free call

For journals & publishers

Start with the audit — ₹4,999 per journal, and the gate to everything else.

DOI care

Every service on one journal profile — each previews first and acts only on your approval.

  • DOI Doctor — check & repairevery DOI tested at doi.org and Crossref; dead links, abstracts, licences, ORCIDs
  • Smart Deposita new DOI from your PDF, Word file, article page, JATS XML or spreadsheet — every value shown with its source, deposited once you confirm it
  • DOI census (Excel)site against Crossref, both directions, with a copy-paste fix per article
  • Backfile DOIsDOIs for older articles that never had one — no per-DOI fee of ours
  • DOIs for conference proceedingsthe conference, the volume and every paper — registered in the organiser's own name
  • Scopus indexing guidethe minimum criteria, the 14 CSAB criteria and how a title is suggested — from Elsevier's own page
  • Embase indexing guidewhat Embase asks of a biomedical journal and how to suggest it
  • Write DOIs into OJSthe verified DOIs pushed onto your article pages through your own API
  • Silent-failure monitorweekly checks of site, OAI-PMH, Scholar tags, ISSN, preservation, hijack lists
  • Journal Radarevery journal, every day: SSL, DNS, redirects, robots.txt, OJS, DOIs, Crossref metadata, broken links — what broke since yesterday first
  • Verified metrics & badgesa public, dated, source-linked metrics page and a "cited by" badge
  • Quality dossier (PDF)one PDF for universities, authors and reviewers
  • Author citation enginethe citation steps emailed to each author from the journal's own mailbox
  • JATS XMLmachine-readable JATS per article
  • Duplicate articlesthe same paper published twice — you choose which copy stays

For authors & researchers

Free to use. Nothing you check is shared with the journal.

For institutions, sponsors & DOI operators

Smart Scholars

Mon–Sat, 10:00–19:00 IST. The Ask AI button on every page answers about our services at any hour.

News

Policies

What we can register a DOI for

20 kinds of record, one account, one place. Every one gets a DOI that resolves, metadata that indexes read, and a record that stays correct afterwards.

Journals

  • Journal articles
  • Journal titles
  • Pending publications
  • Peer reviews
  • Preprints & posted content

Books & conferences

  • Books
  • Book chapters
  • Book series
  • Book sets
  • Conference proceedings
  • Proceedings series
  • Conference papers

Other research output

  • Theses & dissertations
  • Reports & working papers
  • Report series
  • Standards
  • Databases
  • Datasets
  • Figures, tables & supplements

Funding

  • Grants & funding awards

Elsewhere

The same company, in the places our publishers already read.
Add Smart Scholars as a preferred source on GoogleSee more of our newsroom in Google’s Top Stories.
Smart Scholars · Every service on one pageNewsroom posts CC BY 4.0 · DOI metadata CC0 · everything else ©Data from OpenAlex (openalex.org), CC0 · Crossref · ISSN Portal · DOAJContact
WhatsApp