Smart Scholars🛡 Scholar Shield🏛 Research Integrity Desk🧩 Portfolio Console📰 Journals🔧 DOI MembersTools🔎 Journal AuditGI GetIndexedDr DOI Doctor

Cite this DOI

10.46243/jstj.2019.v4.i3.93 · A New Passive Islanding Detection Method under Balanced Islanding Condition For Hybrid Distributed Generation System

APA (7th edition)

A.Pandian (2019). A New Passive Islanding Detection Method under Balanced Islanding Condition For Hybrid Distributed Generation System. *Journal of Science & Technology*, *04*(03), 26–36. https://doi.org/10.46243/jstj.2019.v4.i3.93

⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.

BibTeX

@article{apandian2019passive,
  author    = {A.Pandian},
  title     = {{A New Passive Islanding Detection Method under Balanced Islanding Condition For Hybrid Distributed Generation System}},
  journal   = {Journal of Science \& Technology},
  year      = {2019},
  month     = {may},
  volume    = {04},
  number    = {03},
  pages     = {26--36},
  publisher = {Longman Publishers},
  issn      = {2456-5660},
  doi       = {10.46243/jstj.2019.v4.i3.93},
  url       = {https://doi.org/10.46243/jstj.2019.v4.i3.93},
  language  = {en},
  abstract  = {To solve the energy consumption demand of the world and environmental problems in the future the distributed generation is considered an alternative approach. In this paper a new passive islanding detection technique was proposed for the Hybrid distributed generation (HDG) system based on changes in negative sequence voltage (NSV) and currents during an unintentional islanding. Islanding is caused in the distributed generation system due to failures in the power grid. As per distribution energy resources interconnection standards, it should be detected within 2 sec with the equipments connected to it. It is difficult to detect islanding during zero power imbalance condition. Sequence analyzer will separate the positive, negative and zero sequence components of voltages and currents from the voltages and currents obtained at the point of common coupling (PCC). During a wide range of power imbalance conditions the change in negative sequence voltage and currents are examined for islanding detection. The simulation shows that this method is free from Non detection zone, even at zero power imbalances between load and distribution generation. The computer simulations made in Matlab/ Simulink laboratory show the effectiveness of this method.}
}

⬇ .bib

RIS (EndNote, Zotero, Mendeley)

TY  - JOUR
TI  - A New Passive Islanding Detection Method under Balanced Islanding Condition For Hybrid Distributed Generation System
AU  - A.Pandian
JO  - Journal of Science & Technology
PY  - 2019
DA  - 2019/05/06/
VL  - 04
IS  - 03
SP  - 26
EP  - 36
PB  - Longman Publishers
SN  - 2456-5660
LA  - en
AB  - To solve the energy consumption demand of the world and environmental problems in the future the distributed generation is considered an alternative approach. In this paper a new passive islanding detection technique was proposed for the Hybrid distributed generation (HDG) system based on changes in negative sequence voltage (NSV) and currents during an unintentional islanding. Islanding is caused in the distributed generation system due to failures in the power grid. As per distribution energy resources interconnection standards, it should be detected within 2 sec with the equipments connected to it. It is difficult to detect islanding during zero power imbalance condition. Sequence analyzer will separate the positive, negative and zero sequence components of voltages and currents from the voltages and currents obtained at the point of common coupling (PCC). During a wide range of power imbalance conditions the change in negative sequence voltage and currents are examined for islanding detection. The simulation shows that this method is free from Non detection zone, even at zero power imbalances between load and distribution generation. The computer simulations made in Matlab/ Simulink laboratory show the effectiveness of this method.
DO  - 10.46243/jstj.2019.v4.i3.93
UR  - https://doi.org/10.46243/jstj.2019.v4.i3.93
ER  -

⬇ .ris

CSL-JSON

{
    "type": "article-journal",
    "id": "10.46243/jstj.2019.v4.i3.93",
    "DOI": "10.46243/jstj.2019.v4.i3.93",
    "URL": "https://doi.org/10.46243/jstj.2019.v4.i3.93",
    "title": "A New Passive Islanding Detection Method under Balanced Islanding Condition For Hybrid Distributed Generation System",
    "source": "Smart Scholars DOI Registry",
    "container-title": "Journal of Science & Technology",
    "author": [
        {
            "family": "A.Pandian"
        }
    ],
    "issued": {
        "date-parts": [
            [
                2019,
                5,
                6
            ]
        ]
    },
    "volume": "04",
    "issue": "03",
    "page": "26-36",
    "publisher": "Longman Publishers",
    "language": "en",
    "abstract": "To solve the energy consumption demand of the world and environmental problems in the future the distributed generation is considered an alternative approach. In this paper a new passive islanding detection technique was proposed for the Hybrid distributed generation (HDG) system based on changes in negative sequence voltage (NSV) and currents during an unintentional islanding. Islanding is caused in the distributed generation system due to failures in the power grid. As per distribution energy resources interconnection standards, it should be detected within 2 sec with the equipments connected to it. It is difficult to detect islanding during zero power imbalance condition. Sequence analyzer will separate the positive, negative and zero sequence components of voltages and currents from the voltages and currents obtained at the point of common coupling (PCC). During a wide range of power imbalance conditions the change in negative sequence voltage and currents are examined for islanding detection. The simulation shows that this method is free from Non detection zone, even at zero power imbalances between load and distribution generation. The computer simulations made in Matlab/ Simulink laboratory show the effectiveness of this method.",
    "ISSN": "2456-5660"
}

⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.

From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjstj.2019.v4.i3.93 gives all four in one JSON answer.

Everything Smart Scholars runsNine sites, one account. A journal starts at the audit; an author starts at Scholar Shield.

For journals & publishers

Start with the audit — it is free, and it is the gate to everything else.

DOI care

Nine services on one journal profile — each previews first and acts only on your approval.

For authors & researchers

Free to use. Nothing you check is shared with the journal.

For institutions, sponsors & DOI operators

Smart Scholars

Mon–Sat, 10:00–19:00 IST. The Ask AI button on every page answers about our services at any hour.

News

Policies

What we can register a DOI for

20 kinds of record, one account, one place. Every one gets a DOI that resolves, metadata that indexes read, and a record that stays correct afterwards.
Journals
  • Journal articles
  • Journal titles
  • Pending publications
  • Peer reviews
  • Preprints & posted content
Books & conferences
  • Books
  • Book chapters
  • Book series
  • Book sets
  • Conference proceedings
  • Proceedings series
  • Conference papers
Other research output
  • Theses & dissertations
  • Reports & working papers
  • Report series
  • Standards
  • Databases
  • Datasets
  • Figures, tables & supplements
Funding
  • Grants & funding awards

Elsewhere

The same company, in the places our publishers already read.
Smart Scholars · Every service on one pageData from OpenAlex (openalex.org), CC0 · Crossref · ISSN Portal · DOAJContact
WhatsApp