Cite this DOI
10.46243/jstj.2018.v3.i6.153 · Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages
APA (7th edition)
Reddy, P., & S.S.Tulasiram (2018). Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages. *Journal of Science & Technology*, *03*(06), 36–42. https://doi.org/10.46243/jstj.2018.v3.i6.153
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{reddy2018analysis,
author = {Reddy, P.Nagarjuna and S.S.Tulasiram},
title = {{Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages}},
journal = {Journal of Science \& Technology},
year = {2018},
month = {nov},
volume = {03},
number = {06},
pages = {36--42},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jstj.2018.v3.i6.153},
url = {https://doi.org/10.46243/jstj.2018.v3.i6.153},
language = {en},
abstract = {The high reliability and safety provided by the compressed gas insulated substations(CGIS) has proved that the they are more advantageous than the conventional air insulated substations. All the parts of the GIS are enclosed in metal enclosures which are filled with SF6gas, which has higher breakdown strength than air. Although superior by the performance, the metallic particle contamination greatly hinders the electrical insulation performance of the Gas insulated substations. The free conducting particles, which arise from the parts of the GIS, are commonly found on the enclosure. They move randomly and on crossing the inter electrode gap and sticking to the inner electrode, they lower the breakdown voltage of GIS. In the present work, the movement of the commonly encountered aluminium and copper wire type metallic particle contaminants of different dimensions, in a single phase gas insulated busduct, are determined, operating under various AC voltages. The simulation results are presented andanalysed}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages AU - Reddy, P.Nagarjuna AU - S.S.Tulasiram JO - Journal of Science & Technology PY - 2018 DA - 2018/11/21/ VL - 03 IS - 06 SP - 36 EP - 42 PB - Longman Publishers SN - 2456-5660 LA - en AB - The high reliability and safety provided by the compressed gas insulated substations(CGIS) has proved that the they are more advantageous than the conventional air insulated substations. All the parts of the GIS are enclosed in metal enclosures which are filled with SF6gas, which has higher breakdown strength than air. Although superior by the performance, the metallic particle contamination greatly hinders the electrical insulation performance of the Gas insulated substations. The free conducting particles, which arise from the parts of the GIS, are commonly found on the enclosure. They move randomly and on crossing the inter electrode gap and sticking to the inner electrode, they lower the breakdown voltage of GIS. In the present work, the movement of the commonly encountered aluminium and copper wire type metallic particle contaminants of different dimensions, in a single phase gas insulated busduct, are determined, operating under various AC voltages. The simulation results are presented andanalysed DO - 10.46243/jstj.2018.v3.i6.153 UR - https://doi.org/10.46243/jstj.2018.v3.i6.153 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jstj.2018.v3.i6.153",
"DOI": "10.46243/jstj.2018.v3.i6.153",
"URL": "https://doi.org/10.46243/jstj.2018.v3.i6.153",
"title": "Analysis Of Particle Contamination In Gas Insulated Busducts Operating On High AC Voltages",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "Reddy",
"given": "P.Nagarjuna"
},
{
"family": "S.S.Tulasiram"
}
],
"issued": {
"date-parts": [
[
2018,
11,
21
]
]
},
"volume": "03",
"issue": "06",
"page": "36-42",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "The high reliability and safety provided by the compressed gas insulated substations(CGIS) has proved that the they are more advantageous than the conventional air insulated substations. All the parts of the GIS are enclosed in metal enclosures which are filled with SF6gas, which has higher breakdown strength than air. Although superior by the performance, the metallic particle contamination greatly hinders the electrical insulation performance of the Gas insulated substations. The free conducting particles, which arise from the parts of the GIS, are commonly found on the enclosure. They move randomly and on crossing the inter electrode gap and sticking to the inner electrode, they lower the breakdown voltage of GIS. In the present work, the movement of the commonly encountered aluminium and copper wire type metallic particle contaminants of different dimensions, in a single phase gas insulated busduct, are determined, operating under various AC voltages. The simulation results are presented andanalysed",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.
From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjstj.2018.v3.i6.153 gives all four in one JSON answer.
