Cite this DOI
10.46243/jstj.2018.v3.i1.169 · Enhancement of Power Quality in Grid Connected Wind Energy System Using STATCOM
APA (7th edition)
K.Prathibha, & K.Madhavilatha (2018). Enhancement of Power Quality in Grid Connected Wind Energy System Using STATCOM. *Journal of Science & Technology*, *03*(01), 40–48. https://doi.org/10.46243/jstj.2018.v3.i1.169
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{kprathibha2018enhancement,
author = {K.Prathibha and K.Madhavilatha},
title = {{Enhancement of Power Quality in Grid Connected Wind Energy System Using STATCOM}},
journal = {Journal of Science \& Technology},
year = {2018},
month = {jan},
volume = {03},
number = {01},
pages = {40--48},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jstj.2018.v3.i1.169},
url = {https://doi.org/10.46243/jstj.2018.v3.i1.169},
language = {en},
abstract = {The operating performance of wind electric generators has considerable stress on the quality of electric power and reliability in the performance power systems [1]. Power quality issues such as voltage dip, harmonic distortion and reliability problems are main considerations in this work. The voltage distortion \& reactive power issues are also considered. Thepowerful MAT LAB tool is used to analyse the power quality issues and other reliability problems in this paper and also the performance of induction generator connected with grid is also analyzed for power quality problems. The compensator is designed to inject reactive power to overcome power quality problems and also for better grid operation. There is a continuous variation in terminal voltage because of the varying wind speed. The addition of STATCOM into the system supports to maintain the active power, reactive power and terminal voltage as constant and STATCOM for steady state and dynamic impact study is presented, and the model is validated by comparing with the actual field data.The wind turbine generators have power electronic based converters canbe effectively utilized for efficient control of power, but they generate harmonics. The modified STATCOM as shunt active filter which is used for reducing system harmonics and to improve the system performance. The STATCOM model is implemented using PIC controller}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - Enhancement of Power Quality in Grid Connected Wind Energy System Using STATCOM AU - K.Prathibha AU - K.Madhavilatha JO - Journal of Science & Technology PY - 2018 DA - 2018/01/08/ VL - 03 IS - 01 SP - 40 EP - 48 PB - Longman Publishers SN - 2456-5660 LA - en AB - The operating performance of wind electric generators has considerable stress on the quality of electric power and reliability in the performance power systems [1]. Power quality issues such as voltage dip, harmonic distortion and reliability problems are main considerations in this work. The voltage distortion & reactive power issues are also considered. Thepowerful MAT LAB tool is used to analyse the power quality issues and other reliability problems in this paper and also the performance of induction generator connected with grid is also analyzed for power quality problems. The compensator is designed to inject reactive power to overcome power quality problems and also for better grid operation. There is a continuous variation in terminal voltage because of the varying wind speed. The addition of STATCOM into the system supports to maintain the active power, reactive power and terminal voltage as constant and STATCOM for steady state and dynamic impact study is presented, and the model is validated by comparing with the actual field data.The wind turbine generators have power electronic based converters canbe effectively utilized for efficient control of power, but they generate harmonics. The modified STATCOM as shunt active filter which is used for reducing system harmonics and to improve the system performance. The STATCOM model is implemented using PIC controller DO - 10.46243/jstj.2018.v3.i1.169 UR - https://doi.org/10.46243/jstj.2018.v3.i1.169 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jstj.2018.v3.i1.169",
"DOI": "10.46243/jstj.2018.v3.i1.169",
"URL": "https://doi.org/10.46243/jstj.2018.v3.i1.169",
"title": "Enhancement of Power Quality in Grid Connected Wind Energy System Using STATCOM",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "K.Prathibha"
},
{
"family": "K.Madhavilatha"
}
],
"issued": {
"date-parts": [
[
2018,
1,
8
]
]
},
"volume": "03",
"issue": "01",
"page": "40-48",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "The operating performance of wind electric generators has considerable stress on the quality of electric power and reliability in the performance power systems [1]. Power quality issues such as voltage dip, harmonic distortion and reliability problems are main considerations in this work. The voltage distortion & reactive power issues are also considered. Thepowerful MAT LAB tool is used to analyse the power quality issues and other reliability problems in this paper and also the performance of induction generator connected with grid is also analyzed for power quality problems. The compensator is designed to inject reactive power to overcome power quality problems and also for better grid operation. There is a continuous variation in terminal voltage because of the varying wind speed. The addition of STATCOM into the system supports to maintain the active power, reactive power and terminal voltage as constant and STATCOM for steady state and dynamic impact study is presented, and the model is validated by comparing with the actual field data.The wind turbine generators have power electronic based converters canbe effectively utilized for efficient control of power, but they generate harmonics. The modified STATCOM as shunt active filter which is used for reducing system harmonics and to improve the system performance. The STATCOM model is implemented using PIC controller",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.
From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjstj.2018.v3.i1.169 gives all four in one JSON answer.
