Cite this DOI
10.46243/jstj.2017.v2.i4.211 · Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement
APA (7th edition)
Reddy, S. B., & Reddy, M. (2017). Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement. *Journal of Science & Technology*, *02*(04), 41–45. https://doi.org/10.46243/jstj.2017.v2.i4.211
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{reddy2017synchronous,
author = {Reddy, S. Balaji and Reddy, M.V.Raghavendra},
title = {{Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement}},
journal = {Journal of Science \& Technology},
year = {2017},
month = {jul},
volume = {02},
number = {04},
pages = {41--45},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jstj.2017.v2.i4.211},
url = {https://doi.org/10.46243/jstj.2017.v2.i4.211},
language = {en},
abstract = {Power Quality means maintaining purely sinusoidal current wave form in phase with a purely sinusoidal voltage wave form throughout in a power system. Due to intensive use of power converters and other non linear loads in industries, an increasing deterioration of the power system voltage and current waveforms has been observed. The most important cause for degrading power quality are harmonic distortion and low power factor. Conventionally, Passive filters have been used as a solution to solve harmonic current problems, but they are not capable of mitigating the low power factor problems. So an improved method of Active Power Filter (APF) used to eliminate the disturbances in current. This paper examines the control of Shunt Active Power Filter (SAPF) with Synchronous Reference Frame (SRF) detection method. Here a twelve pulse diode bridge rectifier will be the non linear load and the switching frequency is set to 10 kHz. Simulation analyses are done using Matlab/Simulink software}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement AU - Reddy, S. Balaji AU - Reddy, M.V.Raghavendra JO - Journal of Science & Technology PY - 2017 DA - 2017/07/13/ VL - 02 IS - 04 SP - 41 EP - 45 PB - Longman Publishers SN - 2456-5660 LA - en AB - Power Quality means maintaining purely sinusoidal current wave form in phase with a purely sinusoidal voltage wave form throughout in a power system. Due to intensive use of power converters and other non linear loads in industries, an increasing deterioration of the power system voltage and current waveforms has been observed. The most important cause for degrading power quality are harmonic distortion and low power factor. Conventionally, Passive filters have been used as a solution to solve harmonic current problems, but they are not capable of mitigating the low power factor problems. So an improved method of Active Power Filter (APF) used to eliminate the disturbances in current. This paper examines the control of Shunt Active Power Filter (SAPF) with Synchronous Reference Frame (SRF) detection method. Here a twelve pulse diode bridge rectifier will be the non linear load and the switching frequency is set to 10 kHz. Simulation analyses are done using Matlab/Simulink software DO - 10.46243/jstj.2017.v2.i4.211 UR - https://doi.org/10.46243/jstj.2017.v2.i4.211 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jstj.2017.v2.i4.211",
"DOI": "10.46243/jstj.2017.v2.i4.211",
"URL": "https://doi.org/10.46243/jstj.2017.v2.i4.211",
"title": "Synchronous Reference Frame Control Based Shunt Active Filter for Power Quality improvement",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "Reddy",
"given": "S. Balaji"
},
{
"family": "Reddy",
"given": "M.V.Raghavendra"
}
],
"issued": {
"date-parts": [
[
2017,
7,
13
]
]
},
"volume": "02",
"issue": "04",
"page": "41-45",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "Power Quality means maintaining purely sinusoidal current wave form in phase with a purely sinusoidal voltage wave form throughout in a power system. Due to intensive use of power converters and other non linear loads in industries, an increasing deterioration of the power system voltage and current waveforms has been observed. The most important cause for degrading power quality are harmonic distortion and low power factor. Conventionally, Passive filters have been used as a solution to solve harmonic current problems, but they are not capable of mitigating the low power factor problems. So an improved method of Active Power Filter (APF) used to eliminate the disturbances in current. This paper examines the control of Shunt Active Power Filter (SAPF) with Synchronous Reference Frame (SRF) detection method. Here a twelve pulse diode bridge rectifier will be the non linear load and the switching frequency is set to 10 kHz. Simulation analyses are done using Matlab/Simulink software",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.
From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjstj.2017.v2.i4.211 gives all four in one JSON answer.
