Cite this DOI
10.46243/jst.2022.v7.i02.pp121-129 · Optimal Placement and Sizing of DGs in Electrical Distribution System using Optimization Techniques
APA (7th edition)
Dr.G.Nageswara Reddy, D. R. (2022). Optimal Placement and Sizing of DGs in Electrical Distribution System using Optimization Techniques. *Journal of Science & Technology*, *7*(2), 121–129. https://doi.org/10.46243/jst.2022.v7.i02.pp121-129
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{drgnageswarareddy2022optimal,
author = {Dr.G.Nageswara Reddy, Dr.G.Nageswara Reddy},
title = {{Optimal Placement and Sizing of DGs in Electrical Distribution System using Optimization Techniques}},
journal = {Journal of Science \& Technology},
year = {2022},
month = {jul},
volume = {7},
number = {2},
pages = {121--129},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jst.2022.v7.i02.pp121-129},
url = {https://doi.org/10.46243/jst.2022.v7.i02.pp121-129},
language = {en},
abstract = {The Electrical energy is produced at the generating station is conveyed to the consumers through a network of transmission and distribution systems That part of power system which distributes electrical power for local use in (DG’s) placement is carried out s ufficient smaller than central power plants and can be connected at nearly any point in power system. It has some benefits they are Voltage control power quality, Loss reduction, System reliability. Distribution generation (DG) is a modular technology that can be sited throughout a utility service to lower the cost of service. The optimization is based on the Constriction-factor Particle Swarm optimization (Cf-PSO) technique and Butterfly Optimization Algorithm (BOA) with efficient mathematical function and global search capability. Shunt capacitor bank plays an important role in Electrical Distribution System ( EDS). It improves the voltage stability, power factor, reduce network losses. To allocate the DG and SC banks optimally in Radial Distribution System to reduce the Power losses, Enhances the voltage profile, to diminish the total voltage deviation (TVD), to expand the voltage stability index (VSI)To finding the optimal site and size of DG’s and SC bank, Butterfly Optimization Algorithm and constriction –factor Particle swarm optimization (Cf -PSO) is applied in IEEE 33 -bus system and IEEE 69 bus RDS}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - Optimal Placement and Sizing of DGs in Electrical Distribution System using Optimization Techniques AU - Dr.G.Nageswara Reddy, Dr.G.Nageswara Reddy JO - Journal of Science & Technology PY - 2022 DA - 2022/07/03/ VL - 7 IS - 2 SP - 121 EP - 129 PB - Longman Publishers SN - 2456-5660 LA - en AB - The Electrical energy is produced at the generating station is conveyed to the consumers through a network of transmission and distribution systems That part of power system which distributes electrical power for local use in (DG’s) placement is carried out s ufficient smaller than central power plants and can be connected at nearly any point in power system. It has some benefits they are Voltage control power quality, Loss reduction, System reliability. Distribution generation (DG) is a modular technology that can be sited throughout a utility service to lower the cost of service. The optimization is based on the Constriction-factor Particle Swarm optimization (Cf-PSO) technique and Butterfly Optimization Algorithm (BOA) with efficient mathematical function and global search capability. Shunt capacitor bank plays an important role in Electrical Distribution System ( EDS). It improves the voltage stability, power factor, reduce network losses. To allocate the DG and SC banks optimally in Radial Distribution System to reduce the Power losses, Enhances the voltage profile, to diminish the total voltage deviation (TVD), to expand the voltage stability index (VSI)To finding the optimal site and size of DG’s and SC bank, Butterfly Optimization Algorithm and constriction –factor Particle swarm optimization (Cf -PSO) is applied in IEEE 33 -bus system and IEEE 69 bus RDS DO - 10.46243/jst.2022.v7.i02.pp121-129 UR - https://doi.org/10.46243/jst.2022.v7.i02.pp121-129 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jst.2022.v7.i02.pp121-129",
"DOI": "10.46243/jst.2022.v7.i02.pp121-129",
"URL": "https://doi.org/10.46243/jst.2022.v7.i02.pp121-129",
"title": "Optimal Placement and Sizing of DGs in Electrical Distribution System using Optimization Techniques",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "Dr.G.Nageswara Reddy",
"given": "Dr.G.Nageswara Reddy"
}
],
"issued": {
"date-parts": [
[
2022,
7,
3
]
]
},
"volume": "7",
"issue": "2",
"page": "121-129",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "The Electrical energy is produced at the generating station is conveyed to the consumers through a network of transmission and distribution systems That part of power system which distributes electrical power for local use in (DG’s) placement is carried out s ufficient smaller than central power plants and can be connected at nearly any point in power system. It has some benefits they are Voltage control power quality, Loss reduction, System reliability. Distribution generation (DG) is a modular technology that can be sited throughout a utility service to lower the cost of service. The optimization is based on the Constriction-factor Particle Swarm optimization (Cf-PSO) technique and Butterfly Optimization Algorithm (BOA) with efficient mathematical function and global search capability. Shunt capacitor bank plays an important role in Electrical Distribution System ( EDS). It improves the voltage stability, power factor, reduce network losses. To allocate the DG and SC banks optimally in Radial Distribution System to reduce the Power losses, Enhances the voltage profile, to diminish the total voltage deviation (TVD), to expand the voltage stability index (VSI)To finding the optimal site and size of DG’s and SC bank, Butterfly Optimization Algorithm and constriction –factor Particle swarm optimization (Cf -PSO) is applied in IEEE 33 -bus system and IEEE 69 bus RDS",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.
From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjst.2022.v7.i02.pp121-129 gives all four in one JSON answer.
