Cite this DOI
10.46243/jst.2021.v6.i05.pp145-152 · JAKUBANY WATER TREATMENT PLANT CORROSION TESTS
APA (7th edition)
Begum, M. (2021). JAKUBANY WATER TREATMENT PLANT CORROSION TESTS. *Journal of Science & Technology*, *06*(05), 145–152. https://doi.org/10.46243/jst.2021.v6.i05.pp145-152
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{begum2021jakubany,
author = {Begum, Ms.Wazida},
title = {{JAKUBANY WATER TREATMENT PLANT CORROSION TESTS}},
journal = {Journal of Science \& Technology},
year = {2021},
month = {sep},
volume = {06},
number = {05},
pages = {145--152},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jst.2021.v6.i05.pp145-152},
url = {https://doi.org/10.46243/jst.2021.v6.i05.pp145-152},
language = {en},
abstract = {Structural degradation in all metallic pipelines is primarily caused by external corrosion, which is dependent on both environmental and operational factors. On the other side, internal corrosion may seriously impair a distribution system's functionality (hydraulics, water quality). Corrosion of water pipes has a significant impact on the long-term performance and reliability of water systems. STN 75 7151 and ASTM D2688-11 are used to assess the test. At the Jakubany water treatment facility, corrosion experiments were conducted on raw and processed water.}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - JAKUBANY WATER TREATMENT PLANT CORROSION TESTS AU - Begum, Ms.Wazida JO - Journal of Science & Technology PY - 2021 DA - 2021/09/01/ VL - 06 IS - 05 SP - 145 EP - 152 PB - Longman Publishers SN - 2456-5660 LA - en AB - Structural degradation in all metallic pipelines is primarily caused by external corrosion, which is dependent on both environmental and operational factors. On the other side, internal corrosion may seriously impair a distribution system's functionality (hydraulics, water quality). Corrosion of water pipes has a significant impact on the long-term performance and reliability of water systems. STN 75 7151 and ASTM D2688-11 are used to assess the test. At the Jakubany water treatment facility, corrosion experiments were conducted on raw and processed water. DO - 10.46243/jst.2021.v6.i05.pp145-152 UR - https://doi.org/10.46243/jst.2021.v6.i05.pp145-152 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jst.2021.v6.i05.pp145-152",
"DOI": "10.46243/jst.2021.v6.i05.pp145-152",
"URL": "https://doi.org/10.46243/jst.2021.v6.i05.pp145-152",
"title": "JAKUBANY WATER TREATMENT PLANT CORROSION TESTS",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "Begum",
"given": "Ms.Wazida"
}
],
"issued": {
"date-parts": [
[
2021,
9,
1
]
]
},
"volume": "06",
"issue": "05",
"page": "145-152",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "Structural degradation in all metallic pipelines is primarily caused by external corrosion, which is dependent on both environmental and operational factors. On the other side, internal corrosion may seriously impair a distribution system's functionality (hydraulics, water quality). Corrosion of water pipes has a significant impact on the long-term performance and reliability of water systems. STN 75 7151 and ASTM D2688-11 are used to assess the test. At the Jakubany water treatment facility, corrosion experiments were conducted on raw and processed water.",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.