Cite this DOI
10.46243/jst.2021.v6.i04.pp125-130 · IOT BASED SALINE LEVEL MONITORING SYSTEM
APA (7th edition)
Ojha, K., Parihar, J., & Brahmankar, G. (2021). IOT BASED SALINE LEVEL MONITORING SYSTEM. *Journal of Science & Technology*, *06*(01), 125–130. https://doi.org/10.46243/jst.2021.v6.i04.pp125-130
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{ojha2021based,
author = {Ojha, Kriti and Parihar, Jatin and Brahmankar, Gouri},
title = {{IOT BASED SALINE LEVEL MONITORING SYSTEM}},
journal = {Journal of Science \& Technology},
year = {2021},
month = {aug},
volume = {06},
number = {01},
pages = {125--130},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jst.2021.v6.i04.pp125-130},
url = {https://doi.org/10.46243/jst.2021.v6.i04.pp125-130},
language = {en},
abstract = {a failure of a person, inattentiveness and a greater number of patients, the saline is totally consumed. Initially, this might be inferred as an event. But the consequences are harmful. Just after the saline finishes, blood rushes back to the saline bottle due to difference in blood pressure and pressure in the empty bottle. Thus, Unique health monitoring systems have being developed with less human interference which will be available at low cost in rural as well as urban areas. The system objective is to trouble-shoot the above-mentioned problem efficiently. By means of this the nurse can monitor the amount of saline even in the control room. An automatic saline level monitoring consists of Level sensors which recognize the status of liquid in the bottle whether it is normal or warning status. The recognition of saline drop rate is quite accurate. The output obtained from the sensor is processed to check whether the saline bottle is empty. When the saline bottle goes below a threshold level, the alarm sound will be produced. So, the system reduces continuous monitoring of the patient by nurses.}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - IOT BASED SALINE LEVEL MONITORING SYSTEM AU - Ojha, Kriti AU - Parihar, Jatin AU - Brahmankar, Gouri JO - Journal of Science & Technology PY - 2021 DA - 2021/08/16/ VL - 06 IS - 01 SP - 125 EP - 130 PB - Longman Publishers SN - 2456-5660 LA - en AB - a failure of a person, inattentiveness and a greater number of patients, the saline is totally consumed. Initially, this might be inferred as an event. But the consequences are harmful. Just after the saline finishes, blood rushes back to the saline bottle due to difference in blood pressure and pressure in the empty bottle. Thus, Unique health monitoring systems have being developed with less human interference which will be available at low cost in rural as well as urban areas. The system objective is to trouble-shoot the above-mentioned problem efficiently. By means of this the nurse can monitor the amount of saline even in the control room. An automatic saline level monitoring consists of Level sensors which recognize the status of liquid in the bottle whether it is normal or warning status. The recognition of saline drop rate is quite accurate. The output obtained from the sensor is processed to check whether the saline bottle is empty. When the saline bottle goes below a threshold level, the alarm sound will be produced. So, the system reduces continuous monitoring of the patient by nurses. DO - 10.46243/jst.2021.v6.i04.pp125-130 UR - https://doi.org/10.46243/jst.2021.v6.i04.pp125-130 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jst.2021.v6.i04.pp125-130",
"DOI": "10.46243/jst.2021.v6.i04.pp125-130",
"URL": "https://doi.org/10.46243/jst.2021.v6.i04.pp125-130",
"title": "IOT BASED SALINE LEVEL MONITORING SYSTEM",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "Ojha",
"given": "Kriti"
},
{
"family": "Parihar",
"given": "Jatin"
},
{
"family": "Brahmankar",
"given": "Gouri"
}
],
"issued": {
"date-parts": [
[
2021,
8,
16
]
]
},
"volume": "06",
"issue": "01",
"page": "125-130",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "a failure of a person, inattentiveness and a greater number of patients, the saline is totally consumed. Initially, this might be inferred as an event. But the consequences are harmful. Just after the saline finishes, blood rushes back to the saline bottle due to difference in blood pressure and pressure in the empty bottle. Thus, Unique health monitoring systems have being developed with less human interference which will be available at low cost in rural as well as urban areas. The system objective is to trouble-shoot the above-mentioned problem efficiently. By means of this the nurse can monitor the amount of saline even in the control room. An automatic saline level monitoring consists of Level sensors which recognize the status of liquid in the bottle whether it is normal or warning status. The recognition of saline drop rate is quite accurate. The output obtained from the sensor is processed to check whether the saline bottle is empty. When the saline bottle goes below a threshold level, the alarm sound will be produced. So, the system reduces continuous monitoring of the patient by nurses.",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.
From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjst.2021.v6.i04.pp125-130 gives all four in one JSON answer.
