Cite this DOI
10.46243/jst.2020.v5.i5.pp35-42 · Analysis and Design of Transmission Tower with Isolated Footing
APA (7th edition)
Longman Publishers (2020). Analysis and Design of Transmission Tower with Isolated Footing. *Journal of Science & Technology*, 35–42. https://doi.org/10.46243/jst.2020.v5.i5.pp35-42
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{anon2020analysis,
title = {{Analysis and Design of Transmission Tower with Isolated Footing}},
journal = {Journal of Science \& Technology},
year = {2020},
month = {aug},
number = {Volume 5},
pages = {35--42},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jst.2020.v5.i5.pp35-42},
url = {https://doi.org/10.46243/jst.2020.v5.i5.pp35-42},
language = {en},
abstract = {A transmission tower is a tall structure, usually a steel lattice tower used to support an overhead power line. They are used in high voltage AC and DC systems. Steel tower structure resting on footings are currently becoming popular in any geographical location for electrical transmission, microwave transmission etc. It is necessary to have an understudy of the behavior of such structures and provide an economical design. To understand the performance of such high rise structures, it is necessary to know their behavior considering the soil structure interaction. Modeling of Transmission tower for the validation purpose is done. The basic soil properties of laterite were also found accordingly. Here the entire transmission tower with the isolated footing is modeled and analyzed in STAAD Pro V8i and STAAD Foundation software. The total load transmitted to each tower leg is found using STAAAD Pro and the size of isolated footing under each tower leg is determined using the STAAD Foundation software respectively. If required the soil structure interaction effects (SSI) can also be found easily}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - Analysis and Design of Transmission Tower with Isolated Footing JO - Journal of Science & Technology PY - 2020 DA - 2020/08/07/ IS - Volume 5 SP - 35 EP - 42 PB - Longman Publishers SN - 2456-5660 LA - en AB - A transmission tower is a tall structure, usually a steel lattice tower used to support an overhead power line. They are used in high voltage AC and DC systems. Steel tower structure resting on footings are currently becoming popular in any geographical location for electrical transmission, microwave transmission etc. It is necessary to have an understudy of the behavior of such structures and provide an economical design. To understand the performance of such high rise structures, it is necessary to know their behavior considering the soil structure interaction. Modeling of Transmission tower for the validation purpose is done. The basic soil properties of laterite were also found accordingly. Here the entire transmission tower with the isolated footing is modeled and analyzed in STAAD Pro V8i and STAAD Foundation software. The total load transmitted to each tower leg is found using STAAAD Pro and the size of isolated footing under each tower leg is determined using the STAAD Foundation software respectively. If required the soil structure interaction effects (SSI) can also be found easily DO - 10.46243/jst.2020.v5.i5.pp35-42 UR - https://doi.org/10.46243/jst.2020.v5.i5.pp35-42 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jst.2020.v5.i5.pp35-42",
"DOI": "10.46243/jst.2020.v5.i5.pp35-42",
"URL": "https://doi.org/10.46243/jst.2020.v5.i5.pp35-42",
"title": "Analysis and Design of Transmission Tower with Isolated Footing",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"issued": {
"date-parts": [
[
2020,
8,
7
]
]
},
"issue": "Volume 5",
"page": "35-42",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "A transmission tower is a tall structure, usually a steel lattice tower used to support an overhead power line. They are used in high voltage AC and DC systems. Steel tower structure resting on footings are currently becoming popular in any geographical location for electrical transmission, microwave transmission etc. It is necessary to have an understudy of the behavior of such structures and provide an economical design. To understand the performance of such high rise structures, it is necessary to know their behavior considering the soil structure interaction. Modeling of Transmission tower for the validation purpose is done. The basic soil properties of laterite were also found accordingly. Here the entire transmission tower with the isolated footing is modeled and analyzed in STAAD Pro V8i and STAAD Foundation software. The total load transmitted to each tower leg is found using STAAAD Pro and the size of isolated footing under each tower leg is determined using the STAAD Foundation software respectively. If required the soil structure interaction effects (SSI) can also be found easily",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.