Cite this DOI
10.46243/jst.2020.v5.i3.pp141-158 · An Isolation Detection Technique for Distributed Generators Based on Inverter for Power Quality Improvement
APA (7th edition)
NarkedamilliSirisha, & N.Sumathi (2020). An Isolation Detection Technique for Distributed Generators Based on Inverter for Power Quality Improvement. *Journal of Science & Technology*, *05*(06), 141–158. https://doi.org/10.46243/jst.2020.v5.i3.pp141-158
⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.
BibTeX
@article{narkedamillisirisha2020isolation,
author = {NarkedamilliSirisha and N.Sumathi},
title = {{An Isolation Detection Technique for Distributed Generators Based on Inverter for Power Quality Improvement}},
journal = {Journal of Science \& Technology},
year = {2020},
volume = {05},
number = {06},
pages = {141--158},
publisher = {Longman Publishers},
issn = {2456-5660},
doi = {10.46243/jst.2020.v5.i3.pp141-158},
url = {https://doi.org/10.46243/jst.2020.v5.i3.pp141-158},
language = {en},
abstract = {In the present paper, an isolation method of detection for the inverter-based system of Distributed generators is proposed and based on perturbing output of reactive power. In the proposed method two sets of the disturbances are designed and have different magnitudes and time durations. In the primary set of reactive power disturbance, amplitudes are periodic and small to break reactive power balancing during isolation process. The secondary set of reactive power disturbance is required for deviation of the frequency beyond its threshold limits. The characteristics of the frequency variations with primary set after isolation are considered and three criterion are designed for switching the disturbances from primary set to secondary set of RPD. All the DGs which are located at different positions have same variation in frequency characteristics and primary set of RPD can be added to different DGs without any further communication at the same instant. Here, synchronization of the secondary set of disturbances can be guaranteed for a system with the multiple DGs. The proposed method is applied to DGs which operate at UPF or for supplying of reactive power to the local loads and the method is validated with cases mentioned in the Matlab/Simulink environment.}
}RIS (EndNote, Zotero, Mendeley)
TY - JOUR TI - An Isolation Detection Technique for Distributed Generators Based on Inverter for Power Quality Improvement AU - NarkedamilliSirisha AU - N.Sumathi JO - Journal of Science & Technology PY - 2020 DA - 2020/// VL - 05 IS - 06 SP - 141 EP - 158 PB - Longman Publishers SN - 2456-5660 LA - en AB - In the present paper, an isolation method of detection for the inverter-based system of Distributed generators is proposed and based on perturbing output of reactive power. In the proposed method two sets of the disturbances are designed and have different magnitudes and time durations. In the primary set of reactive power disturbance, amplitudes are periodic and small to break reactive power balancing during isolation process. The secondary set of reactive power disturbance is required for deviation of the frequency beyond its threshold limits. The characteristics of the frequency variations with primary set after isolation are considered and three criterion are designed for switching the disturbances from primary set to secondary set of RPD. All the DGs which are located at different positions have same variation in frequency characteristics and primary set of RPD can be added to different DGs without any further communication at the same instant. Here, synchronization of the secondary set of disturbances can be guaranteed for a system with the multiple DGs. The proposed method is applied to DGs which operate at UPF or for supplying of reactive power to the local loads and the method is validated with cases mentioned in the Matlab/Simulink environment. DO - 10.46243/jst.2020.v5.i3.pp141-158 UR - https://doi.org/10.46243/jst.2020.v5.i3.pp141-158 ER -
CSL-JSON
{
"type": "article-journal",
"id": "10.46243/jst.2020.v5.i3.pp141-158",
"DOI": "10.46243/jst.2020.v5.i3.pp141-158",
"URL": "https://doi.org/10.46243/jst.2020.v5.i3.pp141-158",
"title": "An Isolation Detection Technique for Distributed Generators Based on Inverter for Power Quality Improvement",
"source": "Smart Scholars DOI Registry",
"container-title": "Journal of Science & Technology",
"author": [
{
"family": "NarkedamilliSirisha"
},
{
"family": "N.Sumathi"
}
],
"issued": {
"date-parts": [
[
2020
]
]
},
"volume": "05",
"issue": "06",
"page": "141-158",
"publisher": "Longman Publishers",
"language": "en",
"abstract": "In the present paper, an isolation method of detection for the inverter-based system of Distributed generators is proposed and based on perturbing output of reactive power. In the proposed method two sets of the disturbances are designed and have different magnitudes and time durations. In the primary set of reactive power disturbance, amplitudes are periodic and small to break reactive power balancing during isolation process. The secondary set of reactive power disturbance is required for deviation of the frequency beyond its threshold limits. The characteristics of the frequency variations with primary set after isolation are considered and three criterion are designed for switching the disturbances from primary set to secondary set of RPD. All the DGs which are located at different positions have same variation in frequency characteristics and primary set of RPD can be added to different DGs without any further communication at the same instant. Here, synchronization of the secondary set of disturbances can be guaranteed for a system with the multiple DGs. The proposed method is applied to DGs which operate at UPF or for supplying of reactive power to the local loads and the method is validated with cases mentioned in the Matlab/Simulink environment.",
"ISSN": "2456-5660"
} ⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.
From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjst.2020.v5.i3.pp141-158 gives all four in one JSON answer.