Smart Scholars🛡 Scholar Shield🏛 Research Integrity Desk🧩 Portfolio Console📰 Journals🔧 DOI MembersTools🔎 Journal AuditGI GetIndexedDr DOI Doctor

Cite this DOI

10.46243/jst.2020.v5.i04.pp215-222 · LC-MS/MS-Based Selective Degradant Separation and Mass Spectral Characterization of Viloxazine

APA (7th edition)

Shivaprasad, Adithyamathur, & Dr.Ratnasre (2020). LC-MS/MS-Based Selective Degradant Separation and Mass Spectral Characterization of Viloxazine. *Journal of Science & Technology*, *05*(04), 215–222. https://doi.org/10.46243/jst.2020.v5.i04.pp215-222

⬇ text Italics are shown as *asterisks* in plain text — the journal or book title and the volume.

BibTeX

@article{shivaprasad2020lcmsmsbased,
  author    = {Shivaprasad and Adithyamathur and Dr.Ratnasre},
  title     = {{LC-MS/MS-Based Selective Degradant Separation and Mass Spectral Characterization of Viloxazine}},
  journal   = {Journal of Science \& Technology},
  year      = {2020},
  month     = {aug},
  volume    = {05},
  number    = {04},
  pages     = {215--222},
  publisher = {Longman Publishers},
  issn      = {2456-5660},
  doi       = {10.46243/jst.2020.v5.i04.pp215-222},
  url       = {https://doi.org/10.46243/jst.2020.v5.i04.pp215-222},
  language  = {en},
  abstract  = {This study presents a unique method for the selective extraction of degradants from API using HPLC and online connection of a SCIEX QTRAP 5500 mass spectrometer with a triple quadrupole mass analyzer and PDA detector. Chromatography was employed using mobile phase ACN: 0.1\% TEA (40:60) \%v/v to separate all degradants on the Agilent Eclipse XDB (150 mm x 4.6 mm, 3.5 μ) column. It was discovered that the maximum absorption occurs at 220 nm, allowing for simultaneous detection unaffected by the placebo matrix. It was decided to approve the recommended RP-HPLC technique in accordance with the general ICH guidelines. The parameters that were considered adequate were specificity, linearity, LoD, LoQ, accuracy, precision, and robustness of validation. The suggested approach demonstrates excellent linearity and robust correlation over the range of 12.5–75 μg/mL. The precision tests' percent RSD was less than 2\%, whilst the accuracy trials yielded consistent recoveries (95–105\%). It may be possible to determine the inherent stability of the drug molecules in the present formulation by doing forced degradation tests and evaluating the degradation products generated under different stress conditions. By using MS/MS analyses, the generated degradants were further described and effectively isolated. Validation studies showed that the recently developed method is stable and sensitive to all degradants. Validation studies show that within the required operating range, the newly created approach was also linear, accurate, precise, robust, and selective.}
}

⬇ .bib

RIS (EndNote, Zotero, Mendeley)

TY  - JOUR
TI  - LC-MS/MS-Based Selective Degradant Separation and Mass Spectral Characterization of Viloxazine
AU  - Shivaprasad
AU  - Adithyamathur
AU  - Dr.Ratnasre
JO  - Journal of Science & Technology
PY  - 2020
DA  - 2020/08/27/
VL  - 05
IS  - 04
SP  - 215
EP  - 222
PB  - Longman Publishers
SN  - 2456-5660
LA  - en
AB  - This study presents a unique method for the selective extraction of degradants from API using HPLC and online connection of a SCIEX QTRAP 5500 mass spectrometer with a triple quadrupole mass analyzer and PDA detector. Chromatography was employed using mobile phase ACN: 0.1% TEA (40:60) %v/v to separate all degradants on the Agilent Eclipse XDB (150 mm x 4.6 mm, 3.5 μ) column. It was discovered that the maximum absorption occurs at 220 nm, allowing for simultaneous detection unaffected by the placebo matrix. It was decided to approve the recommended RP-HPLC technique in accordance with the general ICH guidelines. The parameters that were considered adequate were specificity, linearity, LoD, LoQ, accuracy, precision, and robustness of validation. The suggested approach demonstrates excellent linearity and robust correlation over the range of 12.5–75 μg/mL. The precision tests' percent RSD was less than 2%, whilst the accuracy trials yielded consistent recoveries (95–105%). It may be possible to determine the inherent stability of the drug molecules in the present formulation by doing forced degradation tests and evaluating the degradation products generated under different stress conditions. By using MS/MS analyses, the generated degradants were further described and effectively isolated. Validation studies showed that the recently developed method is stable and sensitive to all degradants. Validation studies show that within the required operating range, the newly created approach was also linear, accurate, precise, robust, and selective.
DO  - 10.46243/jst.2020.v5.i04.pp215-222
UR  - https://doi.org/10.46243/jst.2020.v5.i04.pp215-222
ER  -

⬇ .ris

CSL-JSON

{
    "type": "article-journal",
    "id": "10.46243/jst.2020.v5.i04.pp215-222",
    "DOI": "10.46243/jst.2020.v5.i04.pp215-222",
    "URL": "https://doi.org/10.46243/jst.2020.v5.i04.pp215-222",
    "title": "LC-MS/MS-Based Selective Degradant Separation and Mass Spectral Characterization of Viloxazine",
    "source": "Smart Scholars DOI Registry",
    "container-title": "Journal of Science & Technology",
    "author": [
        {
            "family": "Shivaprasad"
        },
        {
            "family": "Adithyamathur"
        },
        {
            "family": "Dr.Ratnasre"
        }
    ],
    "issued": {
        "date-parts": [
            [
                2020,
                8,
                27
            ]
        ]
    },
    "volume": "05",
    "issue": "04",
    "page": "215-222",
    "publisher": "Longman Publishers",
    "language": "en",
    "abstract": "This study presents a unique method for the selective extraction of degradants from API using HPLC and online connection of a SCIEX QTRAP 5500 mass spectrometer with a triple quadrupole mass analyzer and PDA detector. Chromatography was employed using mobile phase ACN: 0.1% TEA (40:60) %v/v to separate all degradants on the Agilent Eclipse XDB (150 mm x 4.6 mm, 3.5 μ) column. It was discovered that the maximum absorption occurs at 220 nm, allowing for simultaneous detection unaffected by the placebo matrix. It was decided to approve the recommended RP-HPLC technique in accordance with the general ICH guidelines. The parameters that were considered adequate were specificity, linearity, LoD, LoQ, accuracy, precision, and robustness of validation. The suggested approach demonstrates excellent linearity and robust correlation over the range of 12.5–75 μg/mL. The precision tests' percent RSD was less than 2%, whilst the accuracy trials yielded consistent recoveries (95–105%). It may be possible to determine the inherent stability of the drug molecules in the present formulation by doing forced degradation tests and evaluating the degradation products generated under different stress conditions. By using MS/MS analyses, the generated degradants were further described and effectively isolated. Validation studies showed that the recently developed method is stable and sensitive to all degradants. Validation studies show that within the required operating range, the newly created approach was also linear, accurate, precise, robust, and selective.",
    "ISSN": "2456-5660"
}

⬇ .json What citeproc and reference managers read; the DOI system hands it out for Accept: application/vnd.citationstyles.csl+json, and so does this registry's resolver.

From the record as registered (version 2) — the record and its history. Programs: https://registry.smartscholars.in/api.php?action=cite&doi=10.46243%2Fjst.2020.v5.i04.pp215-222 gives all four in one JSON answer.

Everything Smart Scholars runsNine sites, one account. A journal starts at the audit; an author starts at Scholar Shield.

For journals & publishers

Start with the audit — it is free, and it is the gate to everything else.

DOI care

Nine services on one journal profile — each previews first and acts only on your approval.

For authors & researchers

Free to use. Nothing you check is shared with the journal.

For institutions, sponsors & DOI operators

Smart Scholars

Mon–Sat, 10:00–19:00 IST. The Ask AI button on every page answers about our services at any hour.

News

Policies

What we can register a DOI for

20 kinds of record, one account, one place. Every one gets a DOI that resolves, metadata that indexes read, and a record that stays correct afterwards.
Journals
  • Journal articles
  • Journal titles
  • Pending publications
  • Peer reviews
  • Preprints & posted content
Books & conferences
  • Books
  • Book chapters
  • Book series
  • Book sets
  • Conference proceedings
  • Proceedings series
  • Conference papers
Other research output
  • Theses & dissertations
  • Reports & working papers
  • Report series
  • Standards
  • Databases
  • Datasets
  • Figures, tables & supplements
Funding
  • Grants & funding awards

Elsewhere

The same company, in the places our publishers already read.
Smart Scholars · Every service on one pageData from OpenAlex (openalex.org), CC0 · Crossref · ISSN Portal · DOAJContact
WhatsApp