{
    "ok": true,
    "doi": "10.46243/jst.2022.v7.i01.pp97-102",
    "events": [
        {
            "seq": 1,
            "kind": "register",
            "at": "2026-09-29 22:00:23",
            "by": "Administrator (admin)",
            "by_kind": "user",
            "note": "registered at Crossref; record read from api.crossref.org",
            "changes": [
                {
                    "path": "abstract.lang",
                    "from": null,
                    "to": "en"
                },
                {
                    "path": "abstract.value",
                    "from": null,
                    "to": "A simple, economical, user -friendly, precise, accurate, robust, rugged and linear analyt ical method developed and validated for estimation (Assay) of Aceclofenac in Active Pharmaceutical Ingredients or bulk drug form.Isocratic HPLC method developed, flow rate is 1.5 ml/min, and column used Hemochrom C18 Intsil (150mm X 4.6 mm X 5 µm), Column temperature used is 25ºC. Mobile phase used is made from 50 volume of buffer consist of 0.1 % orthophosphoric acid and 50 volumes of organic phase consist of 90% Acetonitrile. The UV detection wavelength is 275 nm. Linearity of the method was observed 50 µ g/ml to 150 µg/ml. The retention time of Aceclofenac is ≈ 6.0 minute. This method was validated as per ICH guideline. (1) This method is very user -friendly and can be used for estimation of Aceclofenac in Active Pharmaceutical Ingredients and Bulk drug for m because Analytical method validation of this method is successfully achieved in present study"
                },
                {
                    "path": "agents.0.name.family",
                    "from": null,
                    "to": "Sachin S. Garad"
                },
                {
                    "path": "agents.0.name.given",
                    "from": null,
                    "to": "Sachin S. Garad"
                },
                {
                    "path": "agents.0.role",
                    "from": null,
                    "to": "author"
                },
                {
                    "path": "agents.0.sequence",
                    "from": null,
                    "to": "first"
                },
                {
                    "path": "agents.1.name.org",
                    "from": null,
                    "to": "Longman Publishers"
                },
                {
                    "path": "agents.1.role",
                    "from": null,
                    "to": "publisher"
                },
                {
                    "path": "characters.0",
                    "from": null,
                    "to": "Language"
                },
                {
                    "path": "container.identifiers.0.medium",
                    "from": null,
                    "to": "electronic"
                },
                {
                    "path": "container.identifiers.0.type",
                    "from": null,
                    "to": "ISSN"
                },
                {
                    "path": "container.identifiers.0.value",
                    "from": null,
                    "to": "2456-5660"
                },
                {
                    "path": "container.issue",
                    "from": null,
                    "to": "Special 1"
                },
                {
                    "path": "container.pages.first",
                    "from": null,
                    "to": "97"
                },
                {
                    "path": "container.pages.last",
                    "from": null,
                    "to": "102"
                },
                {
                    "path": "container.titles.0.type",
                    "from": null,
                    "to": "PrincipalTitle"
                },
                {
                    "path": "container.titles.0.value",
                    "from": null,
                    "to": "Journal of Science &amp; Technology"
                },
                {
                    "path": "container.type",
                    "from": null,
                    "to": "Journal"
                },
                {
                    "path": "container.volume",
                    "from": null,
                    "to": "7"
                },
                {
                    "path": "dates.date_type",
                    "from": null,
                    "to": "PublicationDate"
                },
                {
                    "path": "dates.online",
                    "from": null,
                    "to": "2022-05-22"
                },
                {
                    "path": "dates.published",
                    "from": null,
                    "to": "2022-05-22"
                },
                {
                    "path": "doi",
                    "from": null,
                    "to": "10.46243/jst.2022.v7.i01.pp97-102"
                },
                {
                    "path": "format",
                    "from": null,
                    "to": "smartscholars-doi-metadata/1.0"
                },
                {
                    "path": "identifiers.0.type",
                    "from": null,
                    "to": "DOI"
                },
                {
                    "path": "identifiers.0.value",
                    "from": null,
                    "to": "10.46243/jst.2022.v7.i01.pp97-102"
                },
                {
                    "path": "language",
                    "from": null,
                    "to": "en"
                },
                {
                    "path": "license.applies_to",
                    "from": null,
                    "to": "vor"
                },
                {
                    "path": "license.start",
                    "from": null,
                    "to": "2022-05-22"
                },
                {
                    "path": "license.url",
                    "from": null,
                    "to": "https://creativecommons.org/licenses/by/4.0/"
                },
                {
                    "path": "links.0.primary",
                    "from": null,
                    "to": true
                },
                {
                    "path": "links.0.return_type",
                    "from": null,
                    "to": "text/html"
                },
                {
                    "path": "links.0.url",
                    "from": null,
                    "to": "https://www.jst.org.in/index.php/pub/article/view/596"
                },
                {
                    "path": "links.1.purpose",
                    "from": null,
                    "to": "text-mining"
                },
                {
                    "path": "links.1.return_type",
                    "from": null,
                    "to": "application/pdf"
                },
                {
                    "path": "links.1.url",
                    "from": null,
                    "to": "https://www.jst.org.in/index.php/pub/article/download/596/529"
                },
                {
                    "path": "links.2.purpose",
                    "from": null,
                    "to": "text-mining"
                },
                {
                    "path": "links.2.return_type",
                    "from": null,
                    "to": "application/xml"
                },
                {
                    "path": "links.2.url",
                    "from": null,
                    "to": "https://www.jst.org.in/index.php/pub/article/download/596/2255"
                },
                {
                    "path": "links.3.purpose",
                    "from": null,
                    "to": "similarity-checking"
                },
                {
                    "path": "links.3.url",
                    "from": null,
                    "to": "https://jst.org.in/admin/uploads/Sachin-Garad.pdf"
                },
                {
                    "path": "modes.0",
                    "from": null,
                    "to": "Visual"
                },
                {
                    "path": "record.issue_number",
                    "from": null,
                    "to": 1
                },
                {
                    "path": "record.registered",
                    "from": null,
                    "to": "2024-02-16"
                },
                {
                    "path": "record.registrant",
                    "from": null,
                    "to": "Longman Publishers"
                },
                {
                    "path": "record.source",
                    "from": null,
                    "to": "crossref-api"
                },
                {
                    "path": "record.source_agency",
                    "from": null,
                    "to": "Crossref (member 25296)"
                },
                {
                    "path": "record.updated",
                    "from": null,
                    "to": "2026-09-17"
                },
                {
                    "path": "references.0.key",
                    "from": null,
                    "to": "ref1"
                },
                {
                    "path": "references.0.unstructured",
                    "from": null,
                    "to": "Validation of Analytical Procedures: text and methodology q2(r1)Current Step 4 version Parent Guideline dated 27 October 1994. www.wikipedia.com"
                },
                {
                    "path": "references.1.doi",
                    "from": null,
                    "to": "10.4103/2229-4708.72233"
                },
                {
                    "path": "references.1.key",
                    "from": null,
                    "to": "ref2"
                },
                {
                    "path": "references.1.unstructured",
                    "from": null,
                    "to": "A. Bose, P.P. Dash, M.K. Sahoo,Simple spectrophotometric methods for estimation of aceclofenac from bulk and formulations, Pharmaceutical Methods, Volume 1, Issue 1,2010,Pages 57-60,ISSN 2229-4708"
                },
                {
                    "path": "references.2.doi",
                    "from": null,
                    "to": "10.1016/s0731-7085(01)00518-0"
                },
                {
                    "path": "references.2.key",
                    "from": null,
                    "to": "ref3"
                },
                {
                    "path": "references.2.unstructured",
                    "from": null,
                    "to": "N.H Zawilla, M Abdul Azim Mohammad, N.M El Kousy, S.M El-MoghazyAly,Determination of aceclofenac in bulk and pharmaceutical formulations"
                },
                {
                    "path": "references.3.doi",
                    "from": null,
                    "to": "10.1016/s0731-7085(01)00518-0"
                },
                {
                    "path": "references.3.key",
                    "from": null,
                    "to": "ref4"
                },
                {
                    "path": "references.3.unstructured",
                    "from": null,
                    "to": "Journal of Pharmaceutical and Biomedical Analysis,Volume 27, Issues 1–2,2002,Pages 243-251,ISSN 0731-7085"
                },
                {
                    "path": "references.4.doi",
                    "from": null,
                    "to": "10.5958/2393-9087.2016.00031.5"
                },
                {
                    "path": "references.4.key",
                    "from": null,
                    "to": "ref5"
                },
                {
                    "path": "references.4.unstructured",
                    "from": null,
                    "to": "Adhao VS (2016) RP-HPLC Method development and validation for the simultaneous estimation of aceclofenac and rabeprazole sodium in the bulk and marketed formulation. Indian Journal of Pharmacy and Pharmacology 3(3):146–151. https://doi.org/10.5958/2393- 9087.2016.00031.5"
                },
                {
                    "path": "references.5.doi",
                    "from": null,
                    "to": "10.3897/pharmacia.67.e57981"
                },
                {
                    "path": "references.5.key",
                    "from": null,
                    "to": "ref6"
                },
                {
                    "path": "references.5.unstructured",
                    "from": null,
                    "to": "Sharmin S, Sohrab MH, Moni F, Afroz F, Rony SR, Akhter S (2020) Simple RP-HPLC method for Aceclofenac quantitative analysis in pharmaceutical tablets. Pharmacia67(4):383-391. https://doi.org/10.3897/pharmacia.67.e57981"
                },
                {
                    "path": "references.6.key",
                    "from": null,
                    "to": "ref7"
                },
                {
                    "path": "references.6.unstructured",
                    "from": null,
                    "to": "Guidance for Industry Analytical Procedures and Methods Validation Chemistry, Manufacturing, and Controls Documentation U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) August 2000 CMC #"
                },
                {
                    "path": "referent",
                    "from": null,
                    "to": "Creation"
                },
                {
                    "path": "structural_type",
                    "from": null,
                    "to": "Digital"
                },
                {
                    "path": "titles.0.lang",
                    "from": null,
                    "to": "en"
                },
                {
                    "path": "titles.0.type",
                    "from": null,
                    "to": "PrincipalTitle"
                },
                {
                    "path": "titles.0.value",
                    "from": null,
                    "to": "A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug"
                },
                {
                    "path": "type",
                    "from": null,
                    "to": "JournalArticle"
                }
            ],
            "record_after": {
                "format": "smartscholars-doi-metadata/1.0",
                "doi": "10.46243/jst.2022.v7.i01.pp97-102",
                "referent": "Creation",
                "type": "JournalArticle",
                "structural_type": "Digital",
                "modes": [
                    "Visual"
                ],
                "characters": [
                    "Language"
                ],
                "titles": [
                    {
                        "value": "A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug",
                        "type": "PrincipalTitle",
                        "lang": "en"
                    }
                ],
                "identifiers": [
                    {
                        "type": "DOI",
                        "value": "10.46243/jst.2022.v7.i01.pp97-102"
                    }
                ],
                "agents": [
                    {
                        "role": "author",
                        "name": {
                            "given": "Sachin S. Garad",
                            "family": "Sachin S. Garad"
                        },
                        "sequence": "first"
                    },
                    {
                        "role": "publisher",
                        "name": {
                            "org": "Longman Publishers"
                        }
                    }
                ],
                "dates": {
                    "published": "2022-05-22",
                    "date_type": "PublicationDate",
                    "online": "2022-05-22"
                },
                "language": "en",
                "container": {
                    "type": "Journal",
                    "titles": [
                        {
                            "value": "Journal of Science &amp; Technology",
                            "type": "PrincipalTitle"
                        }
                    ],
                    "identifiers": [
                        {
                            "type": "ISSN",
                            "value": "2456-5660",
                            "medium": "electronic"
                        }
                    ],
                    "volume": "7",
                    "issue": "Special 1",
                    "pages": {
                        "first": "97",
                        "last": "102"
                    }
                },
                "links": [
                    {
                        "url": "https://www.jst.org.in/index.php/pub/article/view/596",
                        "return_type": "text/html",
                        "primary": true
                    },
                    {
                        "url": "https://www.jst.org.in/index.php/pub/article/download/596/529",
                        "purpose": "text-mining",
                        "return_type": "application/pdf"
                    },
                    {
                        "url": "https://www.jst.org.in/index.php/pub/article/download/596/2255",
                        "purpose": "text-mining",
                        "return_type": "application/xml"
                    },
                    {
                        "url": "https://jst.org.in/admin/uploads/Sachin-Garad.pdf",
                        "purpose": "similarity-checking"
                    }
                ],
                "abstract": {
                    "value": "A simple, economical, user -friendly, precise, accurate, robust, rugged and linear analyt ical method developed and validated for estimation (Assay) of Aceclofenac in Active Pharmaceutical Ingredients or bulk drug form.Isocratic HPLC method developed, flow rate is 1.5 ml/min, and column used Hemochrom C18 Intsil (150mm X 4.6 mm X 5 µm), Column temperature used is 25ºC. Mobile phase used is made from 50 volume of buffer consist of 0.1 % orthophosphoric acid and 50 volumes of organic phase consist of 90% Acetonitrile. The UV detection wavelength is 275 nm. Linearity of the method was observed 50 µ g/ml to 150 µg/ml. The retention time of Aceclofenac is ≈ 6.0 minute. This method was validated as per ICH guideline. (1) This method is very user -friendly and can be used for estimation of Aceclofenac in Active Pharmaceutical Ingredients and Bulk drug for m because Analytical method validation of this method is successfully achieved in present study",
                    "lang": "en"
                },
                "license": {
                    "url": "https://creativecommons.org/licenses/by/4.0/",
                    "start": "2022-05-22",
                    "applies_to": "vor"
                },
                "references": [
                    {
                        "key": "ref1",
                        "unstructured": "Validation of Analytical Procedures: text and methodology q2(r1)Current Step 4 version Parent Guideline dated 27 October 1994. www.wikipedia.com"
                    },
                    {
                        "key": "ref2",
                        "doi": "10.4103/2229-4708.72233",
                        "unstructured": "A. Bose, P.P. Dash, M.K. Sahoo,Simple spectrophotometric methods for estimation of aceclofenac from bulk and formulations, Pharmaceutical Methods, Volume 1, Issue 1,2010,Pages 57-60,ISSN 2229-4708"
                    },
                    {
                        "key": "ref3",
                        "doi": "10.1016/s0731-7085(01)00518-0",
                        "unstructured": "N.H Zawilla, M Abdul Azim Mohammad, N.M El Kousy, S.M El-MoghazyAly,Determination of aceclofenac in bulk and pharmaceutical formulations"
                    },
                    {
                        "key": "ref4",
                        "doi": "10.1016/s0731-7085(01)00518-0",
                        "unstructured": "Journal of Pharmaceutical and Biomedical Analysis,Volume 27, Issues 1–2,2002,Pages 243-251,ISSN 0731-7085"
                    },
                    {
                        "key": "ref5",
                        "doi": "10.5958/2393-9087.2016.00031.5",
                        "unstructured": "Adhao VS (2016) RP-HPLC Method development and validation for the simultaneous estimation of aceclofenac and rabeprazole sodium in the bulk and marketed formulation. Indian Journal of Pharmacy and Pharmacology 3(3):146–151. https://doi.org/10.5958/2393- 9087.2016.00031.5"
                    },
                    {
                        "key": "ref6",
                        "doi": "10.3897/pharmacia.67.e57981",
                        "unstructured": "Sharmin S, Sohrab MH, Moni F, Afroz F, Rony SR, Akhter S (2020) Simple RP-HPLC method for Aceclofenac quantitative analysis in pharmaceutical tablets. Pharmacia67(4):383-391. https://doi.org/10.3897/pharmacia.67.e57981"
                    },
                    {
                        "key": "ref7",
                        "unstructured": "Guidance for Industry Analytical Procedures and Methods Validation Chemistry, Manufacturing, and Controls Documentation U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) August 2000 CMC #"
                    }
                ],
                "record": {
                    "registrant": "Longman Publishers",
                    "registered": "2024-02-16",
                    "updated": "2026-09-17",
                    "issue_number": 1,
                    "source": "crossref-api",
                    "source_agency": "Crossref (member 25296)"
                }
            },
            "url_after": "https://www.jst.org.in/index.php/pub/article/view/596",
            "sha256_before": null,
            "sha256_after": "366e73c3d7b478f5e434b5a41549e735ca4e5a8a97e34fe34d2717bb70265062"
        },
        {
            "seq": 2,
            "kind": "update",
            "at": "2026-09-29 23:59:41",
            "by": "Administrator (admin)",
            "by_kind": "user",
            "note": "record re-read from api.crossref.org",
            "changes": [
                {
                    "path": "container.titles.0.value",
                    "from": "Journal of Science &amp; Technology",
                    "to": "Journal of Science & Technology"
                }
            ],
            "record_after": {
                "format": "smartscholars-doi-metadata/1.0",
                "doi": "10.46243/jst.2022.v7.i01.pp97-102",
                "referent": "Creation",
                "type": "JournalArticle",
                "structural_type": "Digital",
                "modes": [
                    "Visual"
                ],
                "characters": [
                    "Language"
                ],
                "titles": [
                    {
                        "value": "A New Simple Validated RP-HPLC-PDA Analytical Method for Estimation of Aceclofenec in Active Pharmaceutical Ingredients and Bulk Drug Form Used as Anti-Anti-Inflammatory Drug",
                        "type": "PrincipalTitle",
                        "lang": "en"
                    }
                ],
                "identifiers": [
                    {
                        "type": "DOI",
                        "value": "10.46243/jst.2022.v7.i01.pp97-102"
                    }
                ],
                "agents": [
                    {
                        "role": "author",
                        "name": {
                            "given": "Sachin S. Garad",
                            "family": "Sachin S. Garad"
                        },
                        "sequence": "first"
                    },
                    {
                        "role": "publisher",
                        "name": {
                            "org": "Longman Publishers"
                        }
                    }
                ],
                "dates": {
                    "published": "2022-05-22",
                    "date_type": "PublicationDate",
                    "online": "2022-05-22"
                },
                "language": "en",
                "container": {
                    "type": "Journal",
                    "titles": [
                        {
                            "value": "Journal of Science & Technology",
                            "type": "PrincipalTitle"
                        }
                    ],
                    "identifiers": [
                        {
                            "type": "ISSN",
                            "value": "2456-5660",
                            "medium": "electronic"
                        }
                    ],
                    "volume": "7",
                    "issue": "Special 1",
                    "pages": {
                        "first": "97",
                        "last": "102"
                    }
                },
                "links": [
                    {
                        "url": "https://www.jst.org.in/index.php/pub/article/view/596",
                        "return_type": "text/html",
                        "primary": true
                    },
                    {
                        "url": "https://www.jst.org.in/index.php/pub/article/download/596/529",
                        "purpose": "text-mining",
                        "return_type": "application/pdf"
                    },
                    {
                        "url": "https://www.jst.org.in/index.php/pub/article/download/596/2255",
                        "purpose": "text-mining",
                        "return_type": "application/xml"
                    },
                    {
                        "url": "https://jst.org.in/admin/uploads/Sachin-Garad.pdf",
                        "purpose": "similarity-checking"
                    }
                ],
                "abstract": {
                    "value": "A simple, economical, user -friendly, precise, accurate, robust, rugged and linear analyt ical method developed and validated for estimation (Assay) of Aceclofenac in Active Pharmaceutical Ingredients or bulk drug form.Isocratic HPLC method developed, flow rate is 1.5 ml/min, and column used Hemochrom C18 Intsil (150mm X 4.6 mm X 5 µm), Column temperature used is 25ºC. Mobile phase used is made from 50 volume of buffer consist of 0.1 % orthophosphoric acid and 50 volumes of organic phase consist of 90% Acetonitrile. The UV detection wavelength is 275 nm. Linearity of the method was observed 50 µ g/ml to 150 µg/ml. The retention time of Aceclofenac is ≈ 6.0 minute. This method was validated as per ICH guideline. (1) This method is very user -friendly and can be used for estimation of Aceclofenac in Active Pharmaceutical Ingredients and Bulk drug for m because Analytical method validation of this method is successfully achieved in present study",
                    "lang": "en"
                },
                "license": {
                    "url": "https://creativecommons.org/licenses/by/4.0/",
                    "start": "2022-05-22",
                    "applies_to": "vor"
                },
                "references": [
                    {
                        "key": "ref1",
                        "unstructured": "Validation of Analytical Procedures: text and methodology q2(r1)Current Step 4 version Parent Guideline dated 27 October 1994. www.wikipedia.com"
                    },
                    {
                        "key": "ref2",
                        "doi": "10.4103/2229-4708.72233",
                        "unstructured": "A. Bose, P.P. Dash, M.K. Sahoo,Simple spectrophotometric methods for estimation of aceclofenac from bulk and formulations, Pharmaceutical Methods, Volume 1, Issue 1,2010,Pages 57-60,ISSN 2229-4708"
                    },
                    {
                        "key": "ref3",
                        "doi": "10.1016/s0731-7085(01)00518-0",
                        "unstructured": "N.H Zawilla, M Abdul Azim Mohammad, N.M El Kousy, S.M El-MoghazyAly,Determination of aceclofenac in bulk and pharmaceutical formulations"
                    },
                    {
                        "key": "ref4",
                        "doi": "10.1016/s0731-7085(01)00518-0",
                        "unstructured": "Journal of Pharmaceutical and Biomedical Analysis,Volume 27, Issues 1–2,2002,Pages 243-251,ISSN 0731-7085"
                    },
                    {
                        "key": "ref5",
                        "doi": "10.5958/2393-9087.2016.00031.5",
                        "unstructured": "Adhao VS (2016) RP-HPLC Method development and validation for the simultaneous estimation of aceclofenac and rabeprazole sodium in the bulk and marketed formulation. Indian Journal of Pharmacy and Pharmacology 3(3):146–151. https://doi.org/10.5958/2393- 9087.2016.00031.5"
                    },
                    {
                        "key": "ref6",
                        "doi": "10.3897/pharmacia.67.e57981",
                        "unstructured": "Sharmin S, Sohrab MH, Moni F, Afroz F, Rony SR, Akhter S (2020) Simple RP-HPLC method for Aceclofenac quantitative analysis in pharmaceutical tablets. Pharmacia67(4):383-391. https://doi.org/10.3897/pharmacia.67.e57981"
                    },
                    {
                        "key": "ref7",
                        "unstructured": "Guidance for Industry Analytical Procedures and Methods Validation Chemistry, Manufacturing, and Controls Documentation U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) August 2000 CMC #"
                    }
                ],
                "record": {
                    "registrant": "Longman Publishers",
                    "registered": "2024-02-16",
                    "updated": "2026-09-17",
                    "issue_number": 1,
                    "source": "crossref-api",
                    "source_agency": "Crossref (member 25296)"
                }
            },
            "url_after": "https://www.jst.org.in/index.php/pub/article/view/596",
            "sha256_before": "366e73c3d7b478f5e434b5a41549e735ca4e5a8a97e34fe34d2717bb70265062",
            "sha256_after": "c630fb7808e9baec06453b5ef6ec2ab6361f79625a0889b759aa66ded419ac7e"
        }
    ]
}